- 16 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with four
type A screws. If mounting the unit on a concrete
wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
2. Measure the wall and mark the centerline. It is
also important to use caution concerning the
location of the installation plate-routing of the
wiring to power outlets is through the walls typi-
cally. Drilling the hole through the wall for pip-
ing connections must be done safely.
• Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left
with the hole slightly slanted to the outdoor side.
• Open the Front Grille.
• Pass Telephone Control Cord Wire through the hole
which the power cord goes through.
• Connect Telephone Control Cord Wire to the phone jack
of telephone PCB of Control Box.
• Fix Telephone Control Cord Wire inside Control box so
as not to disconnect.
• Close the Front Grille.
Installation Plate
Type "A" screw
5-7mm
(3/16"~5/16")
Indoor
WALL
Outdoor
Installation plate
Ø70mm
Left rear piping
Right rear piping
C
D
B
A
Ø70mm
A
B
C
D
S6(9k)
75
12
80
12
SR2(12k)
0
40
20
40
ST2(18k/24k)
105
0
210
0
CHASSIS
(Grade)
Distance (mm)
How to Fix Installation Plate
Drill a Hole in the Wall
Drain hose junction
• Remove the rubber stopple in the desired drain direc-
tion.
• Insert drain hose into the handle of drain pan, and join
drain hose and connecting hose according to the figure
by.
Only the
desired direction
Connecting
part
Adhesive
Drain
hose
Содержание AS-H0966KA2
Страница 60: ...P NO 3828A20462S MAY 2008 ...