background image

14   |   InTroduCTIon

Single Zone 

Art Cool Gallery Owner

’s Manual

Due to our policy of continuous product innovation, some specifications may change without notification.

advanCed funCtiOns

Jet Cool/Heat operation - 

Auto Changeover operation

Follow the operational directions in this section to work with advanced functionality and features of the Art Cool Gallery Wall Mounted system.

Jet Cool/Heat Operation

rapid cooling and heating of room Temperature

This functionality allows you to rapidly cool indoor air (during sum-

mer months) or warm indoor air (during winter months).
1.  Press         to turn on the power.
2.  Press the 

Jet

 button          .

• 

In Jet Cool Mode, unit operates at a setpoint of 65 

°F (18 °C) for a 

duration of 30 minutes.

• In Jet Heat Mode, 

unit operates at a setpoint

 of 86 °F (30 °C) for a 

duration of 30 minutes.

• Jet Cool/Heat Mode cannot be run during Air Circulation, Auto, or 

Auto Changeover mode.

• This function may not be supported on all Single Zone Inverter models.

auto Clean Operation

Indoor Air Purification

While in Cooling and Dehumidifying Mode, the air conditioner 

generates moisture on the interior of the indoor unit. The Auto Clean 

operation is used to remove this type of moisture.
1.  Press          to turn on the power.

2.  Press            to start dehumidifying operation.

• 

          is displayed on the Remote Control display screen.

• If the power is turned off, the fan will operate for 30 minutes and will 

clean the inside of the indoor unit.

• Some buttons (functionality) will not operate while the system is in 

Auto Cleaning Mode.

artificial intelligence

Auto operation - (cooling only Models)

During this functionality, the fan speed and the temperature adjust 

automatically, based on room temperature.
1.  Press          to turn on the power.

2.  Press the 

Mode

 button         repeatedly to select Auto operation 

         (see icon in Figure 8 below).

3.  Press the up and down buttons                      to select the desired 

numerical operation code for cooling/heating strength. See the 

table in Figure 8 below for a description of each numerical value.

• During  the Artificial  Intelligence  Mode,  you  cannot  adjust  the  fan 

speed. 

• During this mode, you can set the air deflector to rotate automatically.

• This function may not be supported on all Single Zone Inverter models.

Code Description

2

Cool

1

Cool slightly 

0

Maintain 

room 

temperature

-1

Heat slightly 

-2

Heat

Figure 8:   Auto Intelligence Screen with Code Description

auto Changeover Operation

This functionality changes the operation mode automatically to main-

tain a set temperature of ± 3.6 °F (±2°C).
1.  Press          to turn on the power.

2.  Press the 

Mode

 button         repeatedly to select Auto operation 

        (see icon display in red box in Figure 9 below).

3.  Press the up and down buttons                      to select the desired 

temperature.

• 

The temperature range is 64.4 °F (18 °C) through 86 °F (30 °C).

4.  Press  

 repeatedly as needed to adjust the fan speed.

Auto Changeover

Figure 9:  Auto Changeover Display

• This function may not be supported on all Single Zone Inverter models.

°c/°f Screen Display

The Single Zone Art Cool Gallery unit can be set in either °C or °F 

temperature readout, by pressing and holding the Room Tempera-

ture button             for 5 seconds.

Содержание Art Cool Gallery Wall Mounted

Страница 1: ...Owner s Manual Art Cool Gallery Wall Mounted 3 4 Ton and 1 Ton Art Cool Gallery Wall Mounted ...

Страница 2: ...ecifications without notice LG Electronics U S A Inc Proprietary Data Notice This document as well as all reports illustrations data information and other materials is the property of LG Electronics U S A Inc and are disclosed by LG Electronics U S A Inc only in confidence This document is for design purposes only ...

Страница 3: ... Interval Cleaning the Air Filter Troubleshooting 18 19 TABLE OF sYMBOLS This symbol indicates a potentially hazardous situation which if not avoided may result in death or serious injury This symbol indicates additional helpful information such as an explanation a comment or a clarification about the subject This symbol indicates a recommendation or tip Recommendations instruct the user to apply ...

Страница 4: ... disconnect the product in the event of a blackout or thunderstorm Failure to do so may result in fire electric shock and or damage Always insure proper equipment ground Failure to do so may result in electric shock and or product failure Be sure a circuit breaker is installed before using the air conditioner Failure to do so may result in electric shock and or product failure Do not connect the g...

Страница 5: ...ioner ventilate the area immediately Failure to do so may result in serious injury and or product failure Usage Use only those parts which are listed in the service parts list Never attempt to modify the equipment because that may result in death serious injury and or product failure Discard the batteries in a safe manner and where there is no danger of excessive heat or fire Failure to do so may ...

Страница 6: ...for han dling the refrigerant and the air conditioner and for disassembling the air conditioner Failure to do so may result in product failure Do not mix the batteries for the remote control with other types of batteries or mix new batteries with used batteries because it may result in product failure Do not recharge or disassemble the batteries because it may result in explosion fire or serious b...

Страница 7: ...s Single Zone Art Cool Gallery The following table shows the available outdoor and indoor units their model numbers along with the factory provided controller Table 1 Single Zone Art Cool Gallery Parts Outdoor Unit Model Btu h Indoor Unit Model Btu h Controller LAU090HVP 9 000 LAU120HVP 12 000 LAN090HVP 9 000 LAN120HVP 12 000 AKB73635607 ...

Страница 8: ...oling or heating Display screen will show adjusted temperature Operation Mode Selection Button Cycles through the operation mode from top left symbols Cooling mode Auto operation or auto changeover Dehumidifying mode Heating mode Fan Speed Button Adjusts the indoor fan speed by pressing repeatedly Also allows for natural air circulation when wavy arrow is displayed Jet Button Heating Cooling Rapid...

Страница 9: ...tion or clears cancels a function When pressing and holding for 3 seconds or longer allows the user to set current time by using the buttons N A Up Down Directional Buttons Used in conjunction with other primary mode and operation buttons Once in desired mode user can press the Up and Down button to move forward or backward in selections For example these buttons can be used to set timer clock set...

Страница 10: ... cover If the display screen of the remote control starts to fade replace the batteries When batteries are removed the temperature unit will be reset to Celsius as the default Installation of the remote control holder should be out of direct sunlight in order to protect the remote control from heat exposure 1 Choose a safe and easily accessible place to attach the remote control holder 2 Using a p...

Страница 11: ...tally activate and operate other electronic devices due to the signal being picked up For optimum operation periodically use a soft cloth to wipe the signal transmitter on the remote control and the receiver on the indoor unit Single Zone Art Cool Gallery Remote Control Indoor Unit Indoor Unit Basic Components Signal Receiver Front Panel Front Panel Hooks 3 Air Discharge Air Filter ON OFF button R...

Страница 12: ...midifying symbol raindrop is displayed on the Remote Control display screen When indoor unit is in dehumidifying mode you cannot adjust the room temperature Temperature is being adjusted automatically While in dehumidifying mode display screen will not show the tem perature value Air Circulation Operation This mode only circulates the indoor air without changing the room temperature The cooling la...

Страница 13: ...ght of the timer display on the display screen 2 Press one of the up or down buttons to select the minutes hours will scroll 3 Press when done to exit the setting mode 1 Press the OFF button under the Timer area of the Remote Control An OFF icon will flicker to the right of the timer display on the display screen 2 Press one of the up or down buttons to select the minutes hours will scroll 3 Press...

Страница 14: ...nality will not operate while the system is in Auto Cleaning Mode Artificial Intelligence Auto Operation Cooling Only Models During this functionality the fan speed and the temperature adjust automatically based on room temperature 1 Press to turn on the power 2 Press the Mode button repeatedly to select Auto operation see icon in Figure 8 below 3 Press the up and down buttons to select the desire...

Страница 15: ...ter models Auto Restart Functionality After a power failure the unit can be programmed to automatically restart reboot and remember its previous settings This function is a factory default setting However should you wish to disable the Auto Restart feature follow the steps below Refer to Figure 10 Disable Auto Restart 1 Open the front cover of the indoor unit by lifting up both sides of the cover ...

Страница 16: ...ns Air filter Every 2 weeks See Air Filter Cleaning Maintenance on page 17 Indoor unit surface Regularly Use a soft dry cloth Do not use bleach or abrasives Outdoor unit Regularly as needed Use steam to clean the heat exchanger coils and the panel vents If needed consult with technician on proper care Table 4 Maintenance and Cleaning Interval Maintenance Precautions Turn off the power and unplug t...

Страница 17: ...hile removing the filter Front panel does not have a locking mechanism so failure to hold the panel open may result in head and bodily injuries 3 Using two hands swing front panel away and then up 4 Starting at one of the top corners of the filter detach the filter from the indoor unit see step 5 in Figure 13 5 Lift out the entire filter once detached from the unit 6 Rinse down the filter and let ...

Страница 18: ...troubleshooting steps that can be taken If the problem persists contact your local service center LG Customer Information Contact LG Customer Information Center immediately if you see any issues as referred to in Table 5 LG Customer Information Center LG Electronics USA 201 James Record Rd SW Huntsville AL 35824 888 865 3026 For USA calls Press 2 for PTAC TTW Press 3 for DFS Multi V Call the insta...

Страница 19: ...g the front of the air conditioner The air filter is dirty Clean the air filter once every 2 weeks See Cleaning Air Filter for more information The room temperature is too high In summer it may take some time to cool indoor air In this case select the jet cool operation to cool indoor air quickly Cold air is escaping from the room Make sure that no cold air is escaping through ventilation points i...

Страница 20: ...ivision 11405 Old Roswell Road Alpharetta Georgia 30009 www lg vrf com DFS OL AK 001 US_014C07 20001747 ISO 9001 2008 LG ELECTRONICS INC LG Electronics Commercial Products Support 1 888 865 3026 USA Follow the prompts for commercial A C products ...

Отзывы: