11. Child Lock function
This function is to operate Air conditioner only by Remocon.
The procedure is as the following
1st
: Press the 2 buttons of the temperature control simultaneously, to raise-to lower on the Display Panel of the
product for more 3 seconds.
2nd
: The buzzer sounds and then the window of Display Panel shows
CL
(CL) mark.
3rd
: To release this function, the reverse again the operating procedure could be done.
❈
During this function is operating, any buttons of Display Panel don't work. But it is possible to operate with
Remote controller.
9. Protection of the evaporator pipe from frosting
• Compressor and outdoor fan stop when indoor pipe temperature is below -2°C and restart at the pipe temperature
is above 12°C.
10. Air Purifying Operation(AP-Z286RC0, AP-Z286R20, AP-Z286R30, AP-Z488TC0)
8. Soft Dry Operation Mode
• During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 2°C, the compressor
OFF temperature is the setting temperature minus 1°C.
• When the room temperature rises over the compressor ON temperature, the operation mode is switched to the Cool-
ing mode.
• When the room temperature falls between the compressor ON temperature and OFF temperature, the operation
mode is switched to the Soft Dry Operation.
• The operation diagram is shown below.
Intake Air Temp.
Indoor Fan Speed
LOW
Selecting
fan speed
Selecting
fan speed
LOW
LOW
LOW
LOW
Compressor
OFF
ON
ON
ON
OFF
OFF
ON
LOW
OFF
Setting Temp.
+2
°
C
(Compressor ON)
Setting Temp.
-1
°
C
(Compresso OFF)
Operation
Cooling
Cooling
operation
Dry operation
3 min.
3 min.
10 min.
maximum
7 min.
maximum
10 min.
Mode Selecting
Operating Mode
Fan Speed
Outdoor
OFF
Initial Starting
of Air purifying
Operation
- Low at the initial
- But could be
switched to Med.
Hi
OFF
- Outdoor not operating
- Fan ope Air puri-
fying operating
Repress Air
purifying
Button or
ON/OFF
Button
When switched
to Air purifying
operation
Selecting Speed
of Main Operating
Mode
ON or OFF
depend on
main operat-
ing
- Outdoor operating
- Main Operating +
Air purifying operating