background image

6

Electric Heater

2. Included Items

Minimum airflow by heater capacity

Electric Heater Static pressure drop factors

If the electric heater has been installed, then the  ESP value  has to be set. 
For every increase in static pressure by 0.01 inWC, the ESP value should be increased by 1.
If the setting ESP value is inappropriate, the provided safety device will turn off the heater
according to the airflow.
* in.wc = inch Water Column, inAq

(Unit: CFM)

Do not use less than minimum airflow.

There is risk of fire or damage to the product.

CAUTION

Use the correctly rated power cable.

There is risk of fire or electric shock.

CAUTION

Heater Capacity(kW)

Static pressure drop (in.wc)

0

0

5

– 0.01

10

– 0.02

15

– 0.04

20

– 0.06

Capacity

(kBtu/h (RT))

Heater Capacity (kW)

5

10

15

20

12(1.0)

380

Not available

Not available

Not available

18(1.5) 

380

Not available  Not available  Not available 

24(2.0) 

480

480

Not available  Not available 

30(2.5) 

630

630

Not available  Not available 

36(3.0) 

780

780

Not available  Not available 

42(3.5) 1000

1000

1000

1000

48(4.0) 1000

1000

1000

1000

54(4.5)

1300

1300

1300

1300

7/8inch
(22.2mm)

1-23/64inch
(34.5mm)

1-23/32inch
(43.7mm)

<Knockout diameter>

MODEL

POWER SUPPLY

CAPACITY

(kW @ 208/230V)

HEATER AMPS. 

(Amps @ 208/230V)

MINIMUM CIRCUIT AMPS. 

(Amps @ 208/230V)

CIRCUIT BREAKER 
(Amps @ 208/230V)

POWER CABLE 

(AWG)

SIZE OF

CONDUIT

(inch(mm))

KNOCKOUT

DIAMETER

(inch(mm))

SINGLE

CIRCUIT

DUAL CIRCUIT

SINGLE

CIRCUIT

DUAL CIRCUIT

SINGLE

CIRCUIT

DUAL CIRCUIT

SINGLE

CIRCUIT

DUAL CIRCUIT

L1,L3

L2,L4

L1,L3

L2,L4

L1,L3

L2,L4

L1,L3

L2,L4

ANEH053B1 208/230, 60Hz, 1Ph

4.3/ 5

20.7/ 21.7

-

-

25.9/ 27.2

-

-

30/30

-

-

10/10

-

-

1/2 (21.3)

7/8 (22.2)

ANEH103B2 208/230, 60Hz, 1Ph

8.7/ 10

41.8/ 43.5

-

-

52.3/ 54.3

-

-

60/60

-

-

6/6

-

-

1 (33.4) 1-23/64 (34.5)

ANEH153B2 208/230, 60Hz, 1Ph

13.0/15

-

41.8/43.5 20.7/21.7

-

52.3/54.3 25.9/27.2

-

60/60

30/30

-

6/6

10/10 1-1/4 (42.3) 1-23/32 (43.7)

ANEH203B2 208/230, 60Hz, 1Ph

17.3/ 20

-

41.8/43.5 41.8/43.5

-

52.3/54.3 52.3/54.3

-

60/60

60/60

-

6/6

6/6

1-1/4 (42.3) 1-23/32 (43.7)

Available power cable

Содержание ANEH053B1

Страница 1: ...rk must be performed in accordance with the national wiring standards by authorized personnel only Please retain this installation manual for future reference after reading it thoroughly TYPE Electric Heater For Vertical Air Handling Unit MODEL Electric Heater ANEH053B1 ANEH103B2 ANEH153B2 ANEH203B2 P NO MFL66300701 ENGLISH FRANÇAIS ESPAÑOL ...

Страница 2: ...om Properly insulate any tubing run inside a room to prevent sweating that can cause dripping and water damage to wall and floors in moist or uneven locatinons Use a raised concrete pad or concrete blocks provide a solid level foundation for the outdoor unit This prevents water damage and abnormal vibration in an area with high winds Securely anchor the outdoor unit down with bolts and a metal fra...

Страница 3: ...Installation Manual 3 Electric Heater INSTALLATION MANUAL TABLE OF CONTENTS 1 Safety Precautions 4 2 Included Items 5 3 Assembly Diagram 7 4 Electrical Wiring 10 ENGLISH ...

Страница 4: ...here is risk of fire or electric shock Always install a dedicated circuit and breaker Improper wiring or installation may cause fire or electric shock Use the correctly rated breaker or fuse There is risk of fire or electric shock Before installation read this manual and carry out the works according to it Before installation be sure to check all the included items However be sure to use all kinds...

Страница 5: ...ty 1 1 1 Model 2 Included Items Unit inch mm Figure Electric Heater 2 Included Items 13 1 8 333 7 9 1 2 241 8 11 16 220 2 15 16 75 4 15 16 126 15 3 16 385 8 16 5 16 415 Bi metal Terminal block Heater bracket Relay Dimension Note Image shown above may vary depends on model capacity ...

Страница 6: ... 0 480 480 Not available Not available 30 2 5 630 630 Not available Not available 36 3 0 780 780 Not available Not available 42 3 5 1000 1000 1000 1000 48 4 0 1000 1000 1000 1000 54 4 5 1300 1300 1300 1300 7 8inch 22 2mm 1 23 64inch 34 5mm 1 23 32inch 43 7mm Knockout diameter MODEL POWER SUPPLY CAPACITY kW 208 230V HEATERAMPS Amps 208 230V MINIMUM CIRCUITAMPS Amps 208 230V CIRCUITBREAKER Amps 208 ...

Страница 7: ... CN_EEV and CN_Motor1 connector in control box Step 1 Open upper front panel and control box cover Step 3 Pull out control box Remove heater panel Mounting bracket Step 4 Remove the additional mounting bracket shown in the figure while installing 5kW and 10kW heater with NJ chassis Bracket Slot Step 5 Install heater The bracket should be inserted in the provided slot Step 6 Attach the heater to pa...

Страница 8: ...inal block Connect earth cable to heater panel CN_Pipe out Red CN_Pipe in white CN_Room Yellow CN_EEV White CN_Motor1 white Heater connector CN_EEV White Step 9 Insert control box Connect the three thermistors CN_Pipe out CN_Pipe in and CN_Room CN_EEV CN_Motor1 and Heater connector in control box Lock nut Conduit mounting plate Conduit Knockout for horizontal left Knockout for upflow Step 7 Remove...

Страница 9: ...here would be reduction in heating capacity while defrosting or oil return operation SW6 ON Automatic Heater operation Heater operates automatically according to the heater logic without ownerʼs intervene SW6 OFF Heater manual operation Ownerʼs involvement is required for on off operation But the heater operation would be as per the heater logic When the wire is exposed the malfunction of the mach...

Страница 10: ...10 Electric Heater 4 Electrical Wiring 4 Electrical Wiring 1 5kW Heater 2 10kW Heater ...

Страница 11: ...Installation Manual 11 ENGLISH 4 Electrical Wiring 3 15kW Heater 4 20kW Heater ...

Страница 12: ...12 Electric Heater ...

Страница 13: ......

Отзывы: