16
Multi Air Conditioner
Installation
Connecting the piping to the indoor unit
and drain hose to drain pipe.
1. Align the center of the pipes and suffi-
ciently tighten the flare nut by hand.
2. Tighten the flare nut with a wrench.
3. Next, extend the indoor unit's drain hose.
Then attach the drain pipe.
Indoor unit tubing
Flare nut
Pipes
Wrench
Indoor unit tubing
Open-end wrench (fixed)
Connection pipe
Flare nut
Vinyl tape(narrow)
Adhesive
Drain pipe
Indoor unit drain hose
Installation Information. For left piping. Follow the instruction below.
Good case
• Press on the upper side of clamp and unfold the tubing to slowly downward.
Bad case
• Bending the pipe from right to left may cause damage to the tubing.
Outside diameter
Torque
mm
inch
N. m
kgf.m
lbf.ft
Ø6.35
1/4
14~18
1.4~1.8
10~13
Ø9.52
3/8
34~42
3.5~4.3
25~31
Ø12.7
1/2
49~61
5.0~6.2
36~45
Ø15.88
5/8
69~82
7.0~8.4
51~60
Ø19.05
3/4
100~120 10.0~12.2 73~88
Содержание AMNW07GDBL1