INSTALLATION OF UNIT
19
ENGLISH
Electronic Wiring
Follow ordinance of your governmental
organization for technical standard related to
electrical equipment, wiring regulations and
guidance of each electric power company.
Use round crimp-style terminals for
connecting wires to the terminal block.
Electric wire
Round crimp-style terminal
Attach insulation sleeve
Air
Conditioner
Main power source
Circuit Breaker
Use a circuit breaker
or time delay fuse.
Cable Type
H07RN-F
WARNING
• Be sure to have authorized electrical
engineers do the electric work using
special circuits in accordance with
regulations and this installation manual.
If power supply circuit has a lack of
capacity or electric work deficiency, it
may cause an electric shock or fire.
!
• The circuit diagram is not subject to
change without notice.
• Be sure to connect wires according to
the circuit diagram.
• Connect the wires firmly, so that not to
be pulled out easily.
• Connect the wires according to color
codes by referring the circuit diagram.
• If the supply cord is damaged, it must
be replaced by a special cord or
assembly available from the
manufacturer of its service agent.
CAUTION
!
• Provide a circuit breaker between power
source and the unit as shown below.
CAUTION
!
• The power cord connected to the
outdoor unit(Main Power supply cable)
should be complied with the following
specifications (Cable type approved by
HAR or SAA).
CAUTION
!
1,MFL67445803,영영 2018. 2. 19. 영영 5:00 Page 19