16
INSTALLATION OF UNIT
ENGLISH
Wired remote controller installation
- Since the room temperature sensor is in the remote controller, the remote controller box should
be installed in a place away from direct sunlight, high humidity and direct supply of cold air to
maintain proper space temperature.
Install the remote controller about 1.2~1.5m(4~5ft) above the floor in an area with good air cir-
culation at an average temperature.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the
remote controller LED's, the remote controller should be installed properly as shown in Fig.5.
(The standard height is 1.2~1.5m(4~5ft) from floor level.)
Direct
Sun ray contact area
1.2~1.5m
(4~5ft)
no
no
no
yes
Figure 5 Typical locations for remote controller