![LG AHNW16809A3 Скачать руководство пользователя страница 66](http://html.mh-extra.com/html/lg/ahnw16809a3/ahnw16809a3_installation-manual_213148066.webp)
Accessories Installation
66
Air-to-Water Heat Pump
DHW Tank and DHW Tank Kit / Solar Thermal Kit
Installing DHW tank requires following considerations :
• DHW tank should be located at the flat place.
• Water quality should be complied with EN 98/83 EC Directives.
• As this water tank is DHW tank (indirect heat exchange), do not use anti water-freezing treatment
like ethylene grycol.
• It is highly recommend to wash out inside of the DHW tank after installation. It ensures generating
clean hot water.
• Near the DHW tank there should be water supply and water drain to easy access and maintenance.
• Set the maximum value of the temperature control device of DHW tank.
While installing DHW tank with DHW tank kit or solar thermal kit, there are some constraints like
below :
• DHW tank should be located under the indoor unit or same height with the indoor unit.
• DHW tank should be located under the solar thermal system.
• Distance between DHw tank sensor or solar thermal sensor should be less than 5 m.
• If there is AC power cable near the sensor cable, the sensor cable should be away from the AC
power cable at least 5 m to prevent electric noise.
Solar
Thermal
System
(Field Supply)
Solar
Collector
(Field Supply)
Water Tank
Water Tank Sensor
(Less than 12 m)
Solar Thermal Sensor
(Less than 12 m)
Water In
Water Out
Water Out
Water In
3way valve
(Field Supply)
Pump
(Field Supply)
1,MFL68681810,영영 2017. 7. 1. 영영 12:55 Page 66