WIRING CONNECTION
11
ENGLISH
Connecting Cables between Indoor Unit and Outdoor Unit
Outdoor
unit
Indoor
unit
1
2
3
1
2
3
The power cable connected to the outdoor unit should be complied with IEC 60245 or HD 22.4 S4
(This equipment shall be provided with a cable set complying with the national regulation.
The connecting cable connected to the outdoor unit should be complied with IEC 60245 or
HD 22.4 S4 (This equipment shall be provided with a cable set complying with the national
regulation.)
If the supply cable is damaged, it must be replaced by a special cable or assembly availible
from the manufacturer of its service agent.
When the connection line between the indoor unit and out-
dooor unit is over 40 m, connect the telecommunication line
and power line separately.
CAUTION
!
GN/
YL
20 mm
35±5 mm
10±3 mm
NORMAL
CROSS-SECTIONAL
AREA 0.75 mm
2
20
mm
GN/
YL
35±5 mm
10±3 mm
Model
Phase(Ø)
Area(Ø)
ABUQ18GM1T0
1
2.5
ABUQ24GM1T0
ABUQ30GM1T0
4.0
ABUQ36GM3T0
ABUQ48LM3T0
3
2.5
ABUQ54LM3T0