Features & Benefits
12 Universal System Air Conditioner
Zone Control:
- It controls the temperature of each zone. Opening
or closing of the damper is controlled by sensing
the temperature of each zone. In the cooling mode,
if the temperature of a particular zone is lower than
set temperature then the damper is closed. On the
other hand if the temperature of a particular zone
is higher then the set temperature damper is open
to provide cooling to the zone & vice versa in the
heating mode.
Tele Control :
- It provides you ease of control. Air conditioner can
be switched on/off by the telephone. It saves time
& energy.
E.S.P. Control:
- Generally, when External Static Pressure increas-
es air volume decreases. But by controlling the
phase of motor while installing the product, E.S.P.
is controlled from 8~10mm Aq, linearly. E.S.P. con-
trol provides required constant air volume irrespec-
tive of ESP change. Desired ESP can also be set
through LCD wired remote. Setting of the desired
ESP gives required combination of ESP and air-
flow.
Electric Heater:
- Electric Heater can be used to provide heat in
addition to cycle heat. It also provide & quick heat-
ing. It can also work as a stand alone heater with
only fan operation.
Self Diagnosis Function:
- This function provides diagnosis of the unit. An
error code will be displayed on the LCD wired
remote controller & diagnosis can be done as per
the code indication. The same is also printed on
key cover of the LCD wired remote controller.
ON
ON
ON
OFF
ON
OFF
OFF
OFF
In Advance by Telephone
Before Coming Home...
In case of Going out
Without Turning off the
Air Conditioner...
Zone A
Zone B
Zone D
Zone C
Air v
olume
2
4
6
8
10
12
E.S.P Control
Air volume
at 2 mmAq.
L
L
M
H
M
H
Air volume
at 10 mmAq.
Содержание ABNC186HLAA
Страница 79: ...Electronic Control Device Service Manual 79 Ceiling Duct Type ...
Страница 80: ...Electronic Control Device 80 Universal System Air Conditioner Ceiling Floor ...
Страница 81: ...Schematic Diagram Service Manual 81 Ceiling Cassette Type Schematic Diagram ...
Страница 83: ...Schematic Diagram Service Manual 83 Ceiling Duct Type BH BE Series ...
Страница 84: ...Schematic Diagram 84 Universal System Air Conditioner Ceiling Floor RY 4WAY RY OUTFAN ...
Страница 119: ...P No 3828A22009A Printed in Korea ...