Installation Manual
53
Function
ENGLISH
It is useful to check the cycle data without LGMV.
Operating Method
Whenever you push the Tact Switch, the cycle information will be shown as below.
h
After 1 page is displayed, subsequently 2 page is displayed.
Tact S/W
Item
Display
18/24/60 k
Example
1 page
2 page
1 time
Low Pressure
890 kpa
‘LP’
’ 89’
2 time
Hi Pressure
2 900 kpa
‘HP’
‘290’
3 time
Discharge Temp.
85 °C
‘DS’
’ 85’
4 time
Cond Out Temp.
-10 °C
‘CS’
‘-10’
5 time
Suction Temp.
-10 °C
‘SS’
‘-10’
6 time
ODU Air Temp.
-10 °C
‘AS’
‘-10’
7 time
Current
15 A
‘A’
‘ 15’
8 time
Voltage
230 V
‘V’
‘230’
9 time
Comp Hz
100 Hz
‘F’
‘100’
10 time
DC Link Voltage
230 V
‘dc’
‘230’
PCB Display(18/24/60 k Model Only)
WARNING
When you push the Tact Switch, use the material non-conducting electricity.
!
TACT_SW
TACT_SW
TACT-SW1
Only 60 k
18 k
24 k