background image

16

Room Air Conditioner

This operation circulates the air without cooling or heating. It can
be activated by pressing the AIR CIRCULATION BUTTON. Once
the air circulation is activated you can select the air speed by
pressing the INDOOR FAN SPEED SELECTOR BUTTON.

The up/down airflow (Vertical airflow) can be
adjusted by using the remote controller.

1. Press the START/STOP BUTTON to start the

unit.

2. Press CHAOS SWING BUTTON.

3. The louvers will swing up & 

down automatically.

4. To stop the louver at a desired 

angle, press          again

The left/right(Horizontal airflow) can be adjusted
by using the remote control.

1. Press the START/STOP BUTTON to start the

unit.

2. Press the HORIZONTAL AIRFLOW 

DIRECTION BUTTON.

3.  The louvers will swing left & 

right automatically.

4. To stop the louvers at a desired 

angle, press         again.

Operating Instructions

Vertical / Horizontal Airflow Direction Control (Optional)

• By pressing the CHAOS SWING BUTTON the horizontal air flow direction is changed automatically based on the chaos

algorithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable as if
enjoying natural breeze.

• Always use the remote controller to adjust the up and down air flow direction. Manually moving the vertical air flow

direction louver by hand could damage the mechanism.When the unit is shut off, the up/down airflow direction louver will
close the air outlet vent of the system.

NOTE

CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically
changed from high to low or vice versa, depending on the ambient temperature.
• In case of inverter type models where there is no AIR CIRCULATION BUTTON, air circulation can be

operated by pressing the PLASMA BUTTON. 

NOTE

This feature is enabled by factory default setting, but you can disable it by pressing the
ON/OFF button for 6 seconds. The unit will beep twice and the indicator lamp(2) will blink 4
times. 
To enable it, press the button again for 6 seconds. The unit will beep twice and the indicator
lamp(1) will blink 4 times.

NOTE

Air Circulation Mode

This function is useful in the situation of power failure. 
When power regains after a failure this feature restore the previous operating condition 
and the air conditioner will run in the same settings.

Auto Restart Function

Содержание A246MP

Страница 1: ...P NO 3828A20894B_v1 www lg com OWNER S MANUAL Please read this manual carefully before operating your set and retain it for future reference TYPE ROOM AIR CONDITIONER AIR CONDITIONER ENGLISH FRANÇAIS ...

Страница 2: ... ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts A Safety Precautions 3 B Electrical Safety 6 Temporary Use of an Adapter 6 Temporary Use of an Extension Cord 6 Symbols used in this Manual 6 C Product Introduction 7 Indoor Units 7 Operation Indication La...

Страница 3: ...securely There is risk of fire or electric shock due to dust water etc Use the correctly rated breaker or fuse There is risk of fire or electric shock Do not modify or extend the power cable If the power cable or cord has scratching or skin peeled off or deteriorated then it must be replaced There is risk of fire or electric shock For installation removal or reinstall always contact the dealer or ...

Страница 4: ... the power supply cable There is risk of electric shock or fire Ventilate the product room from time to time when operating it together with a stove or heating element etc Oxygen deficiency can occur and hence harm your health Turn the main power off and unplug the unit when cleaning or repairing the product There is risk of electric shock When the product is not to be used for a long time disconn...

Страница 5: ... used in the system If air enters the refrigerant system an excessively high pressure results causing equipment damage or injury If the refrigerant gas leaks during the installation ventilate the area immediately Otherwise it can be harmful for your health Dismantling the unit treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards Replace...

Страница 6: ...enuine adapter available from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage Never use the appli...

Страница 7: ... panel LED indicators Art Cool Type Display panel LED indicators Art Cool Type Wide Display panel LED indicators Signal receiver Front panel Air discharge Power cord Plasma filter Air filter Signal receiver Front panel Air inlet Air discharge Power cord Plasma filter Air filter Air inlet Plasma filter Optional Air filter Air outlet Front grille ON OFF button Signal receiver Grille tab Flap Horizon...

Страница 8: ...n Inverter Model only Defrost mode Power Display Indicates the setting temperature and operation mode Lights up during defrost mode or hot start operation Heat pump model only Lights up during outdoor unit operation Cooling model only Outdoor unit operation OUT DOOR Hot start operation Stops the indoor fan in heating operation for minutes to prevent cold air from blowing out from unit In defrost m...

Страница 9: ...arts fading replace both of the batteries 4 Use 2 AAA 1 5 volt batteries NOTE 1 Choose a suitable place where its safe easy to reach 2 Fix the holder to wall etc with the supplied screws firmly 3 Slide the remote controller inside the holder 1 Remote controller should never be exposed to direct sunlight 2 Signal transmitter receiver should always be clean for proper communication Use a soft cloth ...

Страница 10: ...Used to set and to cancel the timer operation 10 SLEEP MODE AUTO BUTTON Used to set sleep mode auto operation 11 AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating ENERGY SAVING COOLING MODE BUTTON OPTIONAL For inverter type models 12 ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature 13 PLASMA BUTTON OPTIONAL Used to start or stop the plasma purifica...

Страница 11: ...Auto Changeover Heat Pump Model For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS For cooling the temperature can be set within 18 C 30 C and for heating the temperature range is 16 C 30 C Set the fan speed with the remote controller You can select the fan speed in four steps low medium high and CHAOS by pressing the INDOOR FAN SPE...

Страница 12: ...or cooling function of the air conditioner But during this operation the controller changes the operation mode automatically to keep the temperature within 2 C with respect to the setting temperature Operating Instructions In this operation mode the actual setting temperature and the fan speed are automatically set by the electronic control logic based on the current room temperature If you feel h...

Страница 13: ...et heat function available only in some models warms up the room quickly by operating at super high fan speed and 30 C setting temperature for 60 minutes Plasma filter is a technology developed by LG to get rid of microscopic contaminants in the intake air by generating a plasma of high charge electrons This plasma kills and destroys the contaminants completely to provide clean and hygienic air Yo...

Страница 14: ...OFF button is pressed If you want to stop operation re press the button ON OFF button Heat pump Model Cooling Model Room Temp 24 C 21 C Room Temp 24 C Room Temp 21 C Operating mode Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High High High Setting Temperature 22 C 22 C 23 C 24 C Test operation During the TEST OPERATION the unit operates in cooling mode at high speed fan ...

Страница 15: ...y dehumidification mode The setting temperature will rise automatically two times by 1 C over next consecutive 30 minutes 2 C in 1 hour for a comfortable sleep Now this will be the final setting temperature as long as sleep mode is functioning NOTE 1 Time can be set only when you press the RESET BUTTON Having replacing the batteries you should press the RESET BUTTON to reset the time Press the Sta...

Страница 16: ...d at the same time to make the human body feel most comfortable as if enjoying natural breeze Always use the remote controller to adjust the up and down air flow direction Manually moving the vertical air flow direction louver by hand could damage the mechanism When the unit is shut off the up down airflow direction louver will close the air outlet vent of the system NOTE CHAOS Air economizes powe...

Страница 17: ...lasma filters behind the air filter should be checked and cleaned once in every 3 months or more often if necessary To remove the filters see the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner If it is dirty wash it with water and dry well in shade an install back in place Deodorizer Filters Remove the deodorizer filters behind the air filter and expose them ...

Страница 18: ...g well reinstall the filters in their original position Front panel Panel hook Plasma filter Plasma filter Front panel 5 Standard Split Type Two different methods to open the front panel based on types of air conditioner as below Type 1 Open the front panel as shown Then pull the filter tab slightly forward to remove the air filter After removing the air filter remove the plasma and deodorizer fil...

Страница 19: ...air conditioner is in operation Keep the room temperature uniform Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room Make sure that the doors and windows are shut thight Avoid opening doors and windows as much as possible to keep the cool air in the room Clean the air filter regularly Blockages in the air filter reduce the airflow and lower cooling and...

Страница 20: ... least every 2 weeks See the Maintenance and Service section When the air conditioner is first turned on you need to allow time for the room to cool down Check for open furnace floor registers and cold air returns Make sure they are correct Check and remove such source or turn it off while using the air conditioner What To Do Possible Causes 1 Anything abnormal such as burning smell loud noise etc...

Отзывы: