ENGLISH
8
15 [Energy Saving]
(Command: j q)
►
To reduce the power consumption of the Signage. You can also
adjust Energy Saving in picture settings.
Transmission
(j)(q)( )([Set ID])( )(Data)(Cr)
Power Saving
Function
Level
Description
7
6
5
4
3
2
1
0
0
0
0
0
Low
Power
0
0
0
0
[Off]
0
0
0
0
Low
Power
0
0
0
1
[Minimum]
0
0
0
0
Low
Power
0
0
1
0
[Medium]
0
0
0
0
Low
Power
0
0
1
1
[Maximum]
0
0
0
0
Low
Power
0
1
0
1
[Screen Off]
0
0
0
0
Low
Power
0
1
0
0
[Auto]
►
‘[Auto]’ is available in Signage that supports ‘Intelligent Sensor’.
Ack
(q)( )([Set ID])( )(OK/NG)(Data)(x)
16 [AUTO CONFIGURATION]
(Command: j u) (Only RGB support
model)
►
To adjust picture position and minimize image shaking
automatically. It works only in RGB (PC) mode.
Transmission
(j)(u)( )([Set ID])( )(Data)(Cr)
Data 01 : To set
Ack
(u)( )([Set ID])( )(OK/NG)(Data)(x)
17 [Equalizer]
(Command : j v)
►
To adjust equalizer.
Transmission
(j)(v)( )([Set ID])( )(Data)(Cr)
MSB
LSB
0
0
0
0
0
0
0
0
Frequency
Data
7 6 5 Frequency
4 3 2 1 0
Step
0 0 0
1st Band
0 0 0 0 0
0 (decimal)
0 0 1
2nd Band
0 0 0 0 1
1 (decimal)
0 1 0
3rd Band
... ... ... ... ...
...
0 1 1
4th Band
1 0 0 1 1
19 (decimal)
1 0 0
5th Band
1 0 1 0 0
20 (decimal)
Ack
(v)( )([Set ID])( )(OK/NG)(Data)(x)
18 Key
(Command: m c)
►
To send IR remote key code.
Transmission
(m)(c)( )([Set ID])( )(Data)(Cr)
Data IR CODES
Ack
(c)( )([Set ID])( )(OK/NG)(Data)(x)
19 Control
Backlight
(Command: m g)
►
To control the backlight.
Transmission
(m)(g)( )([Set ID])( )(Data)(Cr)
Data Min : 00 to Max : 64
Ack
(g)( )([Set ID])( )(OK/NG)(Data)(x)