27

INSTALLATION MENU

No Signal Image

 

-

Set to On or Off.

 

-

It is a mode to decide whether to use no signal image when there is no signal.

External Speaker

Volume Control

 

-

Selects the volume control method of an external speaker.  
You can select ‘Off’, ‘Int Variable’,’ Fixed.’,’Ext Variable’ by ^    pressing button. 
Ext Variable uses the External Vol Up/Down Control Line to change the volume up to 1 Watts.  
Int variable is linked to the main volume OSD and change the volume 0 - 1 Watts.   
Fixed produces a fixed output. The default is Off.

Output

 

-

This item is enabled when Volume Control is set to Fixed. You can choose one of 7 steps.(0.01/0.03/0.05/0.1/0.2/0.5/1 
Watts). The Default is 1 Watt.

Set ID Setup

Set ID Lock

 

-

 Set the ‘Set ID’ item in ‘GENERAL’ Menu whether to activate or not.

 

-

 Set to On(Work) or Off(Do Not Work).

Set ID

 

-

 Set the ‘Set ID’ of TV Set with 1~99.

Содержание 55EW961H

Страница 1: ...INSTALLATION MANUAL OLED TV Please read this manual carefully before operating your set and retain it for future reference www lg com EW96 ...

Страница 2: ...Programme Update 19 Power On Default 19 Aux Source Setting 19 Power Management 19 RadioVideo Blank 19 Factory Reset 20 NETWORK 20 MAC Address 20 Network Setting 21 IP Stream Control 21 Wake On LAN 21 PRO CENTRIC 22 Mode 22 WORF 22 Room Number Setting 23 MediaType 23 Receive Data 23 Native EPG 24 GENERAL 24 Configuration Setup 27 External Speaker 27 Set ID Setup 28 Power Saving 28 HCEC Setup 30 Clo...

Страница 3: ...rol and Intelligent1 sensors Power Indicator Joystick Button2 1 Intelligent sensor Adjusts the image quality and brightness based on the surrounding environment 2 Joystick Button This button is located below theTV screen NOTE y y You can set the power indicator light to on or off by selecting General in the main menus ...

Страница 4: ...will search the pre defined channel earlier than all channels Only DVB C The frequencies of pre defined channels are below Germany 51000 858000 778000 698000 618000 538000 458000 378000 298000 218000 138000 khz Philippines 6Mhz 57000 651000 591000 531000 471000 411000 351000 291000 231000 171000 111000 khz Other Country 50000 842000 762000 682000 602000 522000 442000 362000 282000 202000 122000 kh...

Страница 5: ...ENG ENGLISH 5 EZMANAGER LANGUAGE COUNTRY SELECTION Except for Iran Please select the Language and Country Some countries need to select the Time Zone Only Iran Please select the Language ...

Страница 6: ...o set the Room Number on theTV If you intend to set Room Number as part of theTV configuration use the Room Number option to assign the Room for thisTV before you continue with additional configuration In the Label field use the Left Right arrow keys to specify a North South East orWest designation for thisTV In the Room Number field you can use the number keys on the Installer Remote to direct en...

Страница 7: ...ENG ENGLISH 7 EZMANAGER 2 This step automatically searches for the Pro Centric Server If was found the Pro Centric data channel select the NEXT ...

Страница 8: ...ENG ENGLISH 8 EZMANAGER 3 Downloading the Pro Centric application files takes few minutes 4 After the installation is completed the following screen will be displayed ...

Страница 9: ...R Manually for Setup 1 Select a Label and or enter the Room Number using the numeric keypad on the remotes or using the virtual keyboard on theTV screen To continue move and select NEXT 2 Please select the MANUAL PRO CENTRIC ...

Страница 10: ...ENG ENGLISH 10 EZMANAGER 3 Configure the appropriate Pro Centric settings in theTV ...

Страница 11: ...ENG ENGLISH 11 EZMANAGER 4 Downloading the Pro Centric application files takes few minutes ...

Страница 12: ...ENG ENGLISH 12 EZMANAGER 5 After the installation is completed the following screen will be displayed ...

Страница 13: ...nstall Utility 1 Select the USB CONFIGURATION TV MANAGER If you have USB Memory for LG_DTV or lg_dtv folder this step shows the USB file list for downloading the items Detail information is described inTV Manager chapter of Installation Menu ...

Страница 14: ...ENG ENGLISH 14 EZMANAGER 2 Downloading the files takes few minutes 3 After the installation is completed the following screen will be displayed ...

Страница 15: ...enient operation for Hotelier and System Integrators TV 1 Press the Setting button for more than 5 seconds using the user remote control programme information will appear at top left on the screen 2 Enter a four digit password and press OK button TheTV is set with the initial password 1 1 0 5 3 Use the button to select the desired menu LG HOTEL MODE 1 Use the button to select the LG HOTEL MODE SET...

Страница 16: ...urn on main power You can set with PWR STD LST PWR always makeTV set On status when turn on main power STD make Stand by status when turn on main power LST makeTVSet work like previous power status As same concept as Power Backup mode If main power were turned off in Power On status TVSet would work in On status If main power were turned off in Stand by status TVSet would work in Stand by status I...

Страница 17: ... Management Manage key usability of Local Front Key and Remote Control When selected to On following IR Operation and Local Key Operation will be worked by below IR Operation y y Decide whether work the LG remote control or not When IR Operation is set to Normal all remote keys are available Use PWR Only makes block all remote keys except power key When IR Operation is set to Block All all normal ...

Страница 18: ...on for 5 seconds to enter Installation Menu is available When select On Enter possible Menu works OSD Display y y Decide to display OSD or not by setting OSD Display as On Display or Off Do not Display When OSD Display is set to Off Do not Display all OSD is not displayed except some exception Although select Off Do not Display the action that press a Menu button for 5 seconds to enter Installatio...

Страница 19: ... input User cannot disable the current input s Aux Source Setting Power Management y y The Power Management feature will turn off the television receiver if no input control command is received from either the Local or IR Key within a selected hours Activity on either of these inputs shall reset the Power Management timer and prevent interruption ofTV viewing This entry can be set to a value which...

Страница 20: ...work connection eitherWired orWireless 2 When connecting viaWired Configures the IP settings of theTV set You can set the IP address subnet mask gateway and DNS server 3 When connecting viaWi Fi use the one of the following network connection methods AP List Connects to the network selected from the AP List Enter the SSID Connects to the wireless AP typed in WPS PBC Connects easily when the button...

Страница 21: ...00 Change step is 10 or 10 IGMP You can set IGMP version 2 or 3 Wake On LAN y y Sets theWake On LAN function to Enable or Disable TheWake On LAN feature enables theTV to receive software updates and or be powered ON upon receipt ofWake Up Frame packets and or Magic Packet data via the wired LAN To facilitate use of this feature note that the appropriate wired connection must be made PRO CENTRIC 1 ...

Страница 22: ... forWORF Room Number Setting WORF Press the OK button in WORF Setting item to go to the WORF menu WhenWORF is set to Enable Hour and Minute items are enabled and then theWORF function is enabled WhenWORF is set to Disable Hour and Minute items are disabled and then theWORF function is disabled Room Number Setting Press the OK button in Room Number Setting item to go to the Change a room number men...

Страница 23: ...tric server is running Server Address is set to Domain Name Domain Name Sets the domain name where the Pro Centric server is running Port Number Sets the actual port or number where the Pro Centric server is running The default value of IP a b c d is 0 and the range is between 0 and 255 The default value of Port is 0 and the range is between 0 and 65535 Receive Data Sets Enable or Disable When it ...

Страница 24: ...When Select RCU is set to Enable You can adjust Number of RCU menu Number of RCU It is a mode to set Number of RCU Number of RCU value range 1 9 When Select RCU is set to Enable Number of RCU value range 0 When Select RCU is set to Disable RCU Remote Control Unit It is special RCU that operates only setted number of RCU inTV ...

Страница 25: ...tor on box viewed towards connector 1 5 6 9 No Signal Signal requirements 1 VCC 2 RX RS232 Standard RS232 specification 3 TX RS232 Standard RS232 specification 4 IR fromTV 5 GND Power ground 6 8 Not connected 7 2 A 5VDC 10 max 100mV ripple 9 1 5 A 12VDC 10 max 100mV ripple One Channel Map If One Channel Map is Enable theTV will operate as below A When theTV is auto scanning it searches both air an...

Страница 26: ...ng is automatically set to Disable If the signal is removed while Auto Sensing automatic input switch is enabled the input returns to the previous setting If the several input are connected by enabling Auto Sensing and the automatic input returns to the previous setting If the several inputs are connected by enabling Auto Sensing and the automatic input switch is performed several times the input ...

Страница 27: ... uses the ExternalVol Up Down Control Line to change the volume up to 1Watts Int variable is linked to the main volume OSD and change the volume 0 1Watts Fixed produces a fixed output The default is Off Output This item is enabled whenVolume Control is set to Fixed You can choose one of 7 steps 0 01 0 03 0 05 0 1 0 2 0 5 1 Watts The Default is 1Watt Set ID Setup Set ID Lock Set the Set ID item in ...

Страница 28: ...mer 2Hour Auto Power Off is disabled HCEC Setup CEC Mode You will have 3 modes to choose Default HCEC and TVLink CEC If Default is selected you can use SIMPLINK which is provided in LGTV Also you can enable and disable SIMPLINK through SIMPLINK MENU If HCEC is selected you can useTVLink HCEC Protocol For more detailed information please refer toTVLink HCEC Protocol document If TVLink CEC is select...

Страница 29: ...ialize This setting will be enabledWhen CEC mode is set as TVLink CEC If Enable is selected TV will change its input source to HDMI1 by any HDMI CEC simulation from a device HTNG Hotel Mode If you use following functions viaTVLink HCEC HTNG Hotel mode will be set as Yes automatically Power On Default StartVolume MaximumVolume MinimumVolume or StartVolume Even if Hotel Mode Operation is set as No a...

Страница 30: ...n model You can select Input according to Clock Source You can select RF or IP when Clock Source is Pro Centric You can selectTV source when Clock Source is TV Input is set to None HCAP Protocol HTNG automatically when Clock Source is Admin y y Programme Frequency Depending on model Sets the Frequency to get the time information when Clock Source is Pro Centric You can select Programme when Clock ...

Страница 31: ...ded App 1 If you want to use a particular app you can choose from the menu you can setting each apps activation 2 You can check or uncheck by pressing OK button Lock Mode If Lock Mode is Yes the following features will be unavailable USB If it is set to Enable USB devices do not work in relative features Exclude S W update Factory Reset If it is set to Enable User Menu General Reset to Initial Set...

Страница 32: ...ed at launcher bar and User can connect toTV by user s Miracast enabled mobile phone orWiDi enabled laptop Media Renderer Media Renderer enables theTV to act as a Media Renderer device to receive content from DLNA Certified devices on the same network Bluetooth Sound Sync Bluetooth Sound Sync enables Bluetooth sound from the mobile device of player If this value is enabled phone can pair to TV and...

Страница 33: ...nstant On mode the SoftAP setting stays unchanged after power off on Use Default If you want to use default password this password was generated randomly you must select Enable in this item Security Key When guests want to useTV s SoftAP function they need this password If you want to change this default password you need to Change Use Default value into Disable Wi Fi Signal Strength You can contr...

Страница 34: ...ss via USB port named as USB Cloning USB cloning process is divided into 2 main processes One is writing the previously savedTV data into theTV and one another is reading of currentTV data into USB memory card To avoid any confusion due to the words it is clearly specified as Import Clone File and Export Clone File in the whole process 2 DataTo Be Cloned The data cloned are the same data cloned by...

Страница 35: ...nd None checked when the is existed in USB And only one item should be checked on each file format when the page is opened If DZM file exist file will be selected previously download file NOTE y y If the DZM file is still in the USB after the download is complete An Ez Download pop up window will appear and list the file types such asTLL EPK or Micom with the previously downloaded lists checked au...

Страница 36: ...ware This feature update EPK ofTV through the hex file in USB The target file is located in LG_DTV folder If there are more than two USB memory Device It is possible to select the USB The download sequence is UpdateTV Software Select file EPK UPDATE ...

Страница 37: ...e This feature update MICOM ofTV through the hex file in USB The target file is located in LG_DTV folder If there are more than two USB memory Device It is possible to select the USB The download sequence is Update Micom Software Select file Micom UPDATE ...

Страница 38: ...ritten to the USB memory card the user can start Import Clone File process with the data file generated and stored in USB memory card As previously warned in Export Clone File process the user should not turnTV off nor unplug the USB memory card The following images might be slightly different than the OSD image ...

Страница 39: ...ile must be done first before Import Clone File process as it generate the file to be used in Export Clone File While writing is in process the user must not turnTV off nor unplug the USB memory card The following images might be slightly different than the OSD image ...

Страница 40: ......

Отзывы: