63
November 2009 50PQ30 Plasma
Voltage Measurements for the Y-SUS Board
Y
Y
-
-
SUS Floating Ground (15V) and (5V) Checks
SUS Floating Ground (15V) and (5V) Checks
Floating Ground checks must be made from Floating
Ground. Use any pin on P204, P203, P205 or P208.
FG5V Test Point
Floating Ground referenced 5V. Used for low
voltage signal processing on the Y-Drive
board. Leaves the Y-SUS board on P207 pins 8
and 9. AND P209 pins 5 and 5.
Checked at J795 (+5V (F) Test Point.
FG15V Test Point
FG15V to develop the Y-Drive signal.
Checked at J644 (+15V (F) Test Point.
Run: 5V
Standby: 0V
Diode Check: 1.94V
Run: 15.2V
Standby: 0V
Diode Check: 1.5V
Location: Bottom Center of the
two large black heat sinks.
Location: Bottom Left
Floating Ground J643
Location