117
November 2009 50PQ30 Plasma
Voltage and Diode Mode Measurements
Diode Mode Readings with all Connectors Disconnected. DVM in the Diode mode.
Open
3.3V
0V
M5 ON
21
1.36V
5V
5V
Stby 5V
23
Open
3.3V
0V
RL On
19
Open
4.6V
0V
5V Det
17
Gnd
Gnd
Gnd
Gnd
15
Gnd
Gnd
Gnd
Gnd
13
1.1V
5V
5V
5V
11
1.1V
5V
5V
5V
9
Gnd
Gnd
Gnd
Gnd
7
Open
12V
0V
12V
5
Gnd
Gnd
Gnd
Gnd
3
Open
17.3V
0V
17V
1
Diode Mode
Run
STBY
Label
Pin
P1006
Pin front
Gnd
Gnd
Gnd
Auto Gnd
22
Open
0V
0V
*Key On
24
Open
3.3V
0V
VS On
20
Open
4.5V
4.6V
AC Det
18
Gnd
Gnd
Gnd
Gnd
16
Gnd
Gnd
Gnd
Gnd
14
1.1V
5V
5V
STBY5V
12
1.1V
5V
5V
5V
10
Gnd
Gnd
Gnd
Gnd
8
Open
12V
0V
12V
6
Gnd
Gnd
Gnd
Gnd
4
Open
17.3V
0V
17V
2
Diode Mode
Run
STBY
Label
Pin
P301 CONNECTOR "Main" to “Power Supply" P813
*Note: If the Key On line is 5V, the Main Power
Switch is open. Stand-By 5V will shut off.
Main Board Plug P1006 to Power Supply Voltages and Diode Check
Main Board Plug P1006 to Power Supply Voltages and Diode Check