2. No Power
(1) Symptom
1) Doesn’t minute discharge at module.
2) Non does not come in into the front LED.
(2) Check following
Is plug in power cord?
Plug in power cord.
Yes
No
Is the Line Filter and Power
Board Cable connected?
Connect the Cable.
Yes
No
Is the Fuse(F801) on
Power Board normal?
Replace the Fuse.
Yes
No
Is the Power Board and 22P of
VSC Board Cable connected?
Connect the Cable.
Yes
No
After the cable connect is removed
to Power Board, authorized the AC
voltage marking on manual.
When ST-BY 5V is not operated,
replace Power Board.