- 18 -
LGE Internal Use Only
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
4.2.5. Adj. method
(1) Auto adj. method
1) Set TV in adj. mode using POWER ON key.
2) Zero calibrate probe then place it on the center of the
Display.
3) Connect Cable.(RS-232C to USB)
4) Select mode in adj. Program and begin adj.
5) When adj. is complete (OK Sign), check adj. status pre
mode.(Warm, Medium, Cool)
6) Remove probe and RS-232C cable to complete adj.
▪ W/B Adj. must begin as start command “wb 00 00”, and
finish as end command “wb 00 ff”, and Adj. offset if need.
(2) Manual adjustment method
1) Set TV in Adj. mode using POWER ON.
2) Zero Calibrate the probe of Color Analyzer, then place it
on the center of LCD module within 10 cm of the surface.
3) Press ADJ key → EZ adjust using adj. R/C → 7. White-
Balance then press the cursor to the right(key ►).
(When right key(►) is pressed 216 Gray internal pattern
will be displayed)
4) One of R Gain / G Gain / B Gain should be fixed at 192,
and the rest will be lowered to meet the desired value.
5) Adjustment is performed in COOL, MEDIUM, WARM 3
modes of color temperature.
** G-fix adjustment
Adjust modes (Cool), Fix the G gain to 172 (default data)
and change the others (G/B Gain).
Adjust two modes(Medium / Warm), Fix the one of R/G/B
gain to 192 (default data) and decrease the others.
If internal pattern is not available, use RF input. In EZ Adj.
menu 7.White Balance, you can select one of 2 Test-
pattern: ON, OFF. Default is inner(ON). By selecting OFF,
you can adjust using RF signal in 216 Gray pattern.
▪ Adjustment condition and cautionary items
1) Lighting condition in surrounding area
Surrounding lighting should be lower 10 lux. Try to
isolate adj. area into dark surrounding.
2) Probe location
- PDP: Color Analyzer (CA-100, CA-100+, CA210) probe
should be firmly attached to the Module
- LCD: Color Analyzer (CA-210) probe should be within
10cm and perpendicular of the module surface
(80°~ 100°)
3) Aging time
- After Aging Start, Keep the Power ON status during 5
Minutes.
- In case of LCD, Back-light on should be checked using
no signal or Full-white pattern.
4.2.6. Reference(White balance adjusmtment coordinate
and color temperature)
▪ Luminance : 206 Gray
▪ Standard color coordinate and temperature using CS-1000
(over 26 inch)
▪
Standard color coordinate and temperature using CA-210(CH 14)
4.2.7. EDGE & IOL LED White balance table
▪ Apply under the color coordinate table, for compensated
aging time.
-gumi & Global
Model : (normal line)LGD
(*) AUO, INX, Sharp, CSOT, BOE model (Cool spec : 13000K)
– 40UH63**-Z*/55UH65**-Z*
Mode
Coordinate
Temp
∆uv
x
y
Cool
0.271
0.270
13000K
0.0000
Medium
0.286
0.289
9300K
0.0000
Warm
0.313
0.329
6500K
0.0000
Mode
Coordinate
Temp
∆uv
x
y
Cool
0.271±0.002
0.270±0.002
13000K 0.0000
Medium
0.286±0.002
0.289±0.002
9300K
0.0000
Warm
0.313±0.002
0.329±0.002
6500K
0.0000
Aging
time
(Min)
Cool
Medium
Warm
x
y
x
y
x
y
271
270
286
289
313
329
1
0-2
282
289
297
308
324
348
2
3-5
281
287
296
306
323
346
3
6-9
279
284
294
303
321
343
4
10-19
277
280
292
299
319
339
5
20-35
275
277
290
296
317
336
6
36-49
274
274
289
293
316
333
7
50-79
273
272
288
291
315
331
8
80-119
272
271
287
290
314
330
9
Over 120
271
270
286
289
313
329
webOS
Cool
Medium
Warm
x
y
x
y
x
y
271
270
285
293
313
329
Target
278
280
293
299
320
339
Содержание 49UH750 Series
Страница 88: ......