Checking order
1.
Check IR cable condition between IR & Main board
2.
Check the st-by 3.5V on the terminal 16.
4. When checking the Pre-Amp when the power is in ON condition, it is normal when the Analog
Tester needle moves slowly, and defective when it does not move at all.
Standard Repair Process Detail Technical Manual
Remote controller operation checking method
D. Function error_ No response in remote controller,
key error
<ALL MODELS>
A27
Established
date
Revised
date
A27
P4000
1
GND
2
+3.5V_WIFI
3
BT_RESET
4
WIFI_DM
5
NC
6
WIFI_DP
7
WOL/WIFI_POWER_ON
8
GND
9
EYE_SDA
10
GND
11
EYE_SCL
12
KEY1
13
GND
14
KEY2
15
IR
16
+3.5V_ST
17
LED_R
18
GND
①
②
③
Error symptom
Content
Copyright © 2015 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
LGE Internal Use Only
Содержание 49LF640V
Страница 62: ......