63
August 2010 42PJ350 Plasma
Diode Mode Readings
taken with all connectors
Disconnected.
DVM in Diode Mode.
Y
Y
-
-
SUS P101 to Control P101 Plug Voltage Checks
SUS P101 to Control P101 Plug Voltage Checks
There are No Stand By
Voltages on this Connector
Gnd
Gnd
Gnd
30
2.81V
1.05V
ER_DN
15
2.81V
0.05V
SET-DN
29
2.81V
1.85V
OC2
14
3.19V
0.23V
CTL_OE
28
1.81V
0.02V
Y_OE
13
2.81V
0.05V
SUS_UP
27
2.80V
2.14V
Dummy_2
12
3.91V
1.23V
Dummy_4
26
Gnd
Gnd
Gnd
11
2.81V
1.04V
Dummy_1
25
Gnd
Gnd
Gnd
10
2.81V
1.97V
Dummy_3
24
Gnd
Gnd
Gnd
9
2.81V
2.75V
SUS_DN
23
Gnd
Gnd
Gnd
8
2.81V
0.59V
CLK
22
1.11V
5V
+5V
7
3.19V
1.05V
Dummy_5
21
1.11V
5V
+5V
6
2.81V
1.50V
STB
20
1.11V
5V
+5V
5
2.81V
0.24V
SET_UP
19
1.11V
5V
+5V
4
2.81V
1.40V
BLK
18
1.24V
18.24V
+15V
3
2.81V
0.26V
ER_UP
17
1.24V
18.24V
+15V
2
2.81V
0V
DATA
16
1.24V
18.24V
+15V
1
Diode
Run
Label
Pin
Diode
Run
Label
Pin
P101 Connector "Y-SUS" to P111 "Control"
c
TIP: Use the Control Board (P101) side of this connector