2. Protect mode
(1) Symptom
1) After lighting up once, it does not discharge minutely from module.
2) The relay falls.(There is an audible “click”.)
3) The color of the front LED turns from green to red.
(2) Check following
Is the Power
Board normal?
Replace the Power Board.
Is the output the normality Low/High
voltage except Stand-by 5V?
Yes
No
No
Is the
each connector
normal?
Replace the connector.
After connecting each connector do
they operate normally?
Yes
No
No
Is the VSC Board
normal?
If it operates normally after
removing the P900, P901
: Replace VSC Board
Is the output voltage normal after
removing P900, P901 of VSC Board?
No
Yes
3. No Raster
(1) Symptom
1) No OSD and image occur at screen.
2) It maintains the condition where the front LED is green
(2) Check following
Does
minute discharge
at Module?
Is output the normality
Low/High voltage except
stand-by 5V?
Is the inverter on?
Check the LCD Module.
Yes
No
Yes
Replace the Power
board.
No
No
Is the LVDS
cable normal?
Reconnect the LVDS cable in P800.
Yes
No
Is the IC700
(FLI8548) Output
normal?
Replace the VSC.
No