- 14 -
LGE Internal Use Only
Copyright © 2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
TROUBLESHOOTING
1. No power
(1) Symptom
1) Doesn't minute discharge at module.
2) Non does not come in into the front LED.
(2) Check following
Plug in the power cord.
No
Yes
Is the power cord
pluged in?
Connect the cable.
No
Is the Line Filter
and Power Board Cable
connected?
Replace the fuse.
No
Is the appropriate
Fuse(F101) on Power
Board?
Connect the Cable.
After removing the cables, connect them to the
Power Board (except the SC101 connection
cable), and change the AC voltage marking to
manual.
When ST-BY 5V does not operate, replace the
Power Board.
No
Is the
Power Board and 13P
of VSC Board Cable
connected?
Yes
Yes
Yes