February 2009 42LH20
28
TEST 1 Power Supply PWB Low Voltage Test
TEST 1 Power Supply PWB Low Voltage Test
AC Should not be applied at any time while adding resistors or while
unplugging connectors as damage to the circuit PWB may occur.
a) The SMPS PWB “MUST” be producing STBY 5V on any of the
pins 7, 8, 9 or 10 (5V).
If 5V Standby is not being generated, the SMPS PWB is defective and
must be replaced. There is no need to continue with the next test.
(b) Unplug P700 on the Main PWB.
TEST 1:
(1) Add a 10K resistor between (5V STBY) pin 7, 8, 9 or 10 and Pin 2
(PWR). Apply AC. This will turn on the power supply.
•
Check that the 24V and 12V power supplies are
turned on, P201 (24V pins 17 and 18) (12V pins 13 and 14)
(2) Remove AC power.
Use P700
Side to insert
resistors
Содержание 42LH20 Series
Страница 1: ...42LH20 42LH20 Direct View LCD Original March 2009 Updated February 11 2010 ...
Страница 41: ...February 2009 42LH20 41 LVDS Video and 12V from Main PWB T T CON Board With Shield CON Board With Shield ...