COMMER
CIAL MODE
63
(Continued from previous page)
The value range is 0 to 63, with 63 as the default,
which gives the user the full range of volume control, if
item 008 MIN VOLUME is also set at 0. Change values
with Left/Right ADJ button. It may be best to set the
same value on every 32LH1DC1.
*Note: The maximum volume level cannot have a value setting lower
than the MIN VOLUME level (described previously).
010 - MUTE DISABLE
Enables or disables sound mute function. If set to 1,
sound cannot be muted, mute is disabled. If set to 0,
sound can be muted.
011 - KEY DEFEAT (Keyboard Defeat)
If set to 1, key defeat prevents the end user from
accessing the on-screen menus with the display front
panel—MENU, SELECT, and Left / Right arrow keys and
TV/AV do not function. If set to 0, those keys do
function.
*Note: The menus can always be accessed by pressing MENU on the
remote.
012 - IR BANKS EN. (IR Banks Enable)
For direct access to a particular Channel Bank. When
enabled, installer can access a channel bank by inputting
the IR code for the bank.
013 - SCAN MODE
Allows variation in setting the On/Off with Channel
UP/DOWN. You may opt for TV channels only; TV
ch Off/ON; TV ch FM radio; TV
ch FM radio + Off/On with these set-tings for
Scan Mode:
SCAN MODE Characteristics
0 Channel up/down keys change
channels only.
1 Channel down below the lowest channel
(or channel up higher than the highest)
and TV turns off.
014 - STRT CH IN SM (Start Channel in Scan Mode)
When set to 1, installs TV On/Off event below the
start channel at TV turn on.
015 - SLEEP TIMER
If set to 1, the SLEEP TIMER feature may be used. If
set to 0, the Sleep Timer is not available.
016 - EN TIMER (Enable On/Off Timers)
If set to 1, Timer function is available to user. Set to 0
to disable On/Off Timer functions. (Clock must be set in
order to use Timers.)
017 - ALARM
Gives the installer the option of making the Alarm
function available to the end user. If set to 1, Alarm
function is available to end user. Set to 0 to disable the
Alarm function.
*Note: The maximum volume level cannot have a value setting lower
than the MIN VOLUME level (described previously).
Installer should leave item 20 FEATURE LEVEL set to 1
(default).
020 - FEATURE LEVEL
Default set to ZEN 1 for LG IR remote
control opera-tion. Set O, P LBL for LG Private
Label IR remote con-trol operation. Warning:
Do not set to “0” or remote will not control
TV.
021 - V-CHIP (Parental Control)
Set to 1 to activate V-Chip (Parental Control); have it
available to end user to filter and control or otherwise
restrict programming content that can appear. Set to 0
to turn V-Chip feature Off, not available to user; no
programming restrictions can be set.
022 - MAX BLK HRS (Maximum Block Hours)
Sets hours from 0 to 99 for the maximum V-Chip
(Parental Control) block hours. Default setting is for 12
blocking hours.
023 - CAPTION LOCK
Set to 1 to restore previous caption On/Off state after
turn Off. If set to 0, captions are always Off at turn
On.
025 - FUNCTION PRE. (Function Preview)
Set to 0 to suppress CHANNEL PREVIEW from the
FUNCTION menu with some Pay-Per-View systems.
027 - HOSPITAL MODE
The default is 2 (which favors most hospitals). With this
setting two things are affected: Channel Banks 1, 2, and
3 are accessible, while Bank 4 is inactive.
028 - CH. OVERIDE (Channel Override)
If set to 1, the user can select channels with either
Channel up/down or by direct keypad entry. If set to 0,
only those channels that are entered for scanning can
be selected.
029 - OLD OCV (On Command Video
TM
)
Set to 1 for operation with systems from On Command