Figure 18 shows how the stack cables are connected between switches in a
stack. Each stacking connection is a 48 Gbps full-duplex high-speed serial link
using proprietary stacking cables. The switch supports a line- and ring-topology
stacking configuration, or can be used stand alone. To ensure minimal disruption
in case a unit or stacking cable fails, we recommend always use a ring-topology.
In line-topology stacking there is a single stack cable connection between each
switch that carries two-way communications across the stack. In ring-topology
stacking, an extra cable is connected between the top and bottom switches
forming a “ring” or “closed-loop.” The closed-loop cable provides a redundant
path for the stack link, so if one link fails, stack communications can still be
maintained.
illustrates a ring-topology stacking configuration.
To connect up to eight switches in a stack, perform the following steps:
1.
Plug one end of the stack cable (ordered separately) in the Down (right)
port of the top unit.
2.
Plug the other end of the stack cable into the Up (left) port of the next unit.
3.
Repeat steps 1 and 2 for each unit in the stack. Form a simple chain starting
at the Down port on the top unit and ending at the Up port on the bottom
unit (stacking up to 8 units).
4.
(Optional) To form a wrap-around topology, plug one end of a stack cable
into the Down port on the bottom unit and the other end into the Up port on
the top unit.
N
OTE
:
SFP transceivers are hot-swappable. The switch does not need to
be powered off before installing or removing a transceiver. However,
always first disconnect the network cable before removing a
transceiver.
N
OTE
:
SFP transceivers are not provided in the switch package.
Содержание iPECS ES-4526G
Страница 1: ...Installation Manual ES 4550G ES 4526G Managed Layer 3 Stackable GE Switch ...
Страница 2: ......
Страница 4: ......
Страница 14: ...COMPLIANCES AND SAFETY STATEMENTS 14 ES 4550G ES 4526G ...
Страница 20: ...TABLES 20 ES 4550G ES 4526G ...
Страница 22: ...FIGURES 22 ES 4550G ES 4526G Figure 30 Crossover Wiring 77 ...
Страница 36: ...CHAPTER 1 Introduction Features and Benifits 36 ES 4550G ES 4526G ...
Страница 44: ...CHAPTER 2 Network Planning Application Notes 44 ES 4550G ES 4526G ...
Страница 70: ...CHAPTER 4 Making Network Connections Cable Labeling and Connection Records 70 ES 4550G ES 4526G ...
Страница 88: ...APPENDIX C Specifications 10GBASE Extender Module SFP 88 ES 4550G ES 4526G ...
Страница 97: ......
Страница 98: ...Printed in China MARCH 2011 ISSUE 1 0 ...