background image

 

Features and Benefits 

 

 

Save up to 59% of power usage with the 

SMC-EZ1016DT/SMC-EZ1024DT switches 

- If PCs connected to the switches are turned off, the 

switches can 

save up to 59%

 for the power used. And 

even under full traffic load, the switches can still save up to 
21% power consumption. 

- If cable length is less than 20 meters, each switch can 

save 

up to 12% 

for the power used. 

 

Auto-negotiation of half or full duplex, and auto-sensing of 

transmission speed, on all ports 

 

Auto configuration for MDI/MDI-X cable connection allows 

connections to servers, workstations, hubs or switches to be 
made with straight-through cabling 

 

ANSI/IEEE 802.3u compliance ensures compatibility with 

standards-based hubs, switches and cards from any vendor 

 

Store-and-forward switching ensures error-free transmission 

 

Half- and full-duplex flow control prevents packets from 

being dropped under heavy loading 

 

Plug-and-play 

 

“At-a-glance” LEDs for port and system status monitoring 

 

Desktop and rack mountable 

Содержание EZ Switch SMC-EZ1016DT

Страница 1: ...USER GUIDE SMC EZ1016DT SMC EZ1024DT EZ SwitchTM 10 100 16 24 port Unmanaged Fast Ethernet Switch ...

Страница 2: ...on or otherwise under any patent or patent rights of LG Er icsson USA Inc LG Ericsson USA Inc reserves the right to change specifications at any time without notice Copyright 2011 LG Ericsson USA Inc All rights reserved LG Ericsson is a registered trademark Other products and company names are trademarks and registered trade marks of their respective holders Technical Support To Contact LG Ericsso...

Страница 3: ...Warranty and Product Registration To register LG Ericsson products and to review the detailed warranty statement please refer to the LG Ericsson Website at http www lgericssonus com ...

Страница 4: ...e interference at his own expense This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation EC Conformance Declaration Class A SMC contact for these products in Europe is SMC Networks Europe ...

Страница 5: ... ED 3 0 80 1000 MHz with 1 kHz AM 80 Modulation 3 V m Electrical fast transient burst according to EN 61000 4 4 2004 ED 2 0 AC DC power supply 1 kV Data Signal lines 0 5 kV Surge immunity test according to EN 61000 4 5 2005 ED 2 0 AC DC Line to Line 1 kV AC DC Line to Earth 2 kV Immunity to conducted disturbances Induced by radio frequency fields EN 61000 4 6 2006 ED 2 2 0 15 80 MHz with 1 kHz AM ...

Страница 6: ...ea Networks The unit must be connected to an earthed grounded outlet to comply with international safety standards Do not connect the unit to an A C outlet power supply without an earth ground connection The appliance coupler the connector to the unit and not the wall plug must have a configuration for mating with an EN 60320 IEC 320 appliance inlet The socket outlet must be near to the unit and e...

Страница 7: ... SJ 3 conductor The cord set must have a rated current capacity of at least 10A The attachment plug must be an earth grounding type with NEMA 5 15P 15 A 125 V or NEMA 6 15P 15 A 250 V configuration Denmark The supply plug must comply with Section 107 2 D1 Standard DK2 1a or DK2 5a Switzerland The supply plug must comply with SEV ASE 1011 U K The supply plug must comply with BS1363 3 pin 13 A and b...

Страница 8: ...l EN 60320 IEC 320 La prise secteur doit se trouver à proximité de l appareil et son accès doit être facile Vous ne pouvez mettre l appareil hors circuit qu en débranchant son cordon électrique au niveau de cette prise L appareil fonctionne à une tension extrêmement basse de sécurité qui est conforme à la norme IEC 60950 Ces conditions ne sont maintenues que si l équipement auquel il est raccordé ...

Страница 9: ...u moins 10 A La prise femelle de branchement doit être du type à mise à la terre mise à la masse et respecter la configuration NEMA 5 15P 15 A 125 V ou NEMA 6 15P 15 A 250 V Danemark La prise mâle d alimentation doit respecterla la section 107 2 D1 de norme DK2 1a ou DK2 5a Cordon électrique Il doit être agréé dans le pays d utilisation Suisse La prise mâle d alimentation doit respecter la norme S...

Страница 10: ...ß an das Gerät nicht der Wandsteckdosenstecker muß einen gemäß EN 60320 IEC 320 konfigurierten Geräteeingang haben Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein Die Stromversorgung des Geräts kann nur durch Herausziehen des Gerätenetzkabels aus der Netzsteckdose unterbrochen werden Der Betrieb dieses Geräts erfolgt unter den SELV Bedingungen Sicherheitskleinstspannung gem...

Страница 11: ...e jack connector in the RJ 45 port This may damage this device Les raccordeurs ne sont pas utilisé pour le système téléphonique Caution Use only twisted pair cables with RJ 45 connectors that conform to FCC standards Warnings in German Achtung Dieses Produkt enthält keine Teile die eine Wartung vom Benutzer benötigen Achtung Installation und Deinstallation des Gerätes müssen von qualifiziertem Ser...

Страница 12: ... product has reached the end of its life Manufacturing Materials There are no hazardous nor ozone depleting materials in this product Documentation All printed documentation for this product uses biodegradable paper that originates from sustained and managed forests The inks used in the printing process are non toxic Purpose This guide details the hardware features of the switch including Its phys...

Страница 13: ...efits 2 Front Panel LEDs 4 Front Panel 4 Rear Panel 4 INSTALLING THE SWITCH 5 Package Contents 5 Selecting a Site 5 Instructions 6 TROUBLESHOOTING 7 Diagnosing Switch Indicators 7 CABLES 8 Cable Specifications 8 10BASE T 100BASE TX Pin Assignments 8 PRODUCT SPECIFICATIONS 9 ...

Страница 14: ...net integration Green Saving Switches The Green Saving technologies are intelligent innovative algorithms that detect link status and distance to best save power while maintaining performance and stability l Power saving by Auto Detection of the number of active ports The SMC EZ1016DT SMC EZ1024DT switches will auto detect the link status and automatically cut off power at a given port during peri...

Страница 15: ...ion of half or full duplex and auto sensing of transmission speed on all ports Auto configuration for MDI MDI X cable connection allows connections to servers workstations hubs or switches to be made with straight through cabling ANSI IEEE 802 3u compliance ensures compatibility with standards based hubs switches and cards from any vendor Store and forward switching ensures error free transmission...

Страница 16: ... functions of the various indicators Port and Switch Status LEDs LED Condition Status Power On Green The switch is receiving power Ports Link Act On The port has established a valid network connection Flashing Traffic is passing through the port Off The port has not established any network connection Front Panel SMC EZ1024DT SMC EZ1016DT Rear Panel The AC power connector is located on the rear pan...

Страница 17: ...able location for the switch o It should be accessible for installing cabling and maintaining the switch o The temperature and humidity should be within the ranges listed in the specifications o The status LEDs should be clearly visible o There should be adequate space approximately two inches on all sides for proper air flow Make sure twisted pair cable is always routed away from power lines fluo...

Страница 18: ...TP cable maximum length 100 meters 328 ft The EZ Switch 10 100 will support up to 16 or 24 PCs All ports on the switch support automatic MDI MDI X operation so you can use straight through cables for all network connections to PCs or servers or to other switches or hubs Note If an attached device does not support auto negotiation the data rate will be sensed automatically and the communication mod...

Страница 19: ...es not light after connection is made Probable Causes o Switch port network card or cable may be defective Possible Solutions o Check that the switch and attached device are both powered on o Be sure the network cable is connected to both devices o Verify that Category 5 or better cable is used for 10 100 Mbps connections and that the length of any cable does not exceed 100 meters 328 feet o Check...

Страница 20: ...00 Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Because all ports on this switch support automatic MDI MDI X operation you can use straight through cables for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to p...

Страница 21: ... 24 RJ 45 10 100 BASE T ports Indicator Panel Power Ports Link Act Dimensions SMC EZ1016DT 21 6x13 3x4 2cm 8 5x5 2x1 7in SMC EZ1024DT 26 7x16 1x4 2cm 10 5x 6 3x1 7in Weight SMC EZ1016DT 870g 1 9 lbs SMC EZ1024DT 1376g 3 lbs MAC Address Table 8 K entries Memory Buffer SMC EZ1016DT 160Kbytes SMC EZ1024DT 160Kbytes Power Consumption SMC EZ1016DT 6 831 Watts SMC EZ1024DT 8 514 Watts Power Requirement ...

Страница 22: ...lity is assumed by LG Ericsson USA Inc for its use nor for any infringements of patents or other rights of third parties which may result from its use No license is granted by implication or otherwise under any patent or patent rights of LG Ericsson USA Inc LG Ericsson USA Inc reserves the right to change specifications at any time without notice Copyright 2011 LG Ericsson USA Inc All rights reser...

Отзывы: