![LFA SACF 25 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/lfa/sacf-25/sacf-25_user-manual_1891162026.webp)
26
Settings and Adjustment
The SACF 25
®
’s settings can be adjusted. Tuning the machine can help with changing the capsule
dose and machine operation.
Speed Adjustments
The SACF 25
®
has three variable frequency drivers (VFDs) for capsule sewing speed, auger speed,
and capsule fill speed. These adjustments either lower or raise the following: the speed at which
the capsules are inserted into the plates, the speed the Auger rotates, and the speed that powder
fills the capsules.
Tools and Materials Needed
• Disposable latex/rubber gloves (for food grade products and to protect hands from grease)
• Hairnet and/or beard net (food grade products only)
• Sterile shoe covers (food grade products only)
Instructions
Note: Wear latex/rubber gloves (and appropriate food grade attire if applicable) during this process.
1. Run the Capsule Sewer and/or Auger for a few seconds to determine the adjustment.
2. Press the arrows to adjust the speeds.
Capsule fill
Auger
Capsule sewing
Note the following:
• Capsule fill weight is increased as the turntable speed is decreased.
• Capsule fill weight is increased as the level of powder in the Powder Hopper is increased.
• Capsule fill rate is increased as the level of powder in the Powder Hopper is increased.