Contents
Contents
Page
1
Description
. . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1
Design and function . . . . . . . . . . . . . . . . . . . . 3
1.2
Standard specification . . . . . . . . . . . . . . . . . . 6
1.3
Technical data . . . . . . . . . . . . . . . . . . . . . . . . 7
1.4
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2
Transportation and storage
. . . . . . . . . . . . 10
3
Installation and connection
. . . . . . . . . . . . 11
3.1
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.2
Filling in of the lubricants . . . . . . . . . . . . . . . 11
3.3
Electrical connections . . . . . . . . . . . . . . . . . 12
3.4
Connection of the flanges . . . . . . . . . . . . . . 14
4
Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.1
Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.2
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.3
Shutdown and storage . . . . . . . . . . . . . . . . . 16
4.4
Changing from vertical to horizontal flow . . . 16
5
Maintenance
. . . . . . . . . . . . . . . . . . . . . . . 18
5.1
Safety information . . . . . . . . . . . . . . . . . . . . 18
5.2
Oil change / gear box . . . . . . . . . . . . . . . . . 19
5.3
Oil change/shaft seal housing . . . . . . . . . . . 19
5.4
Cleaning the fan cowl and the cooling fins . . 20
5.5
Cleaning the dirt trap . . . . . . . . . . . . . . . . . . 20
5.6
Cleaning the pumping chamber . . . . . . . . . . 20
5.7
Cleaning the valve of the pressure
balance line . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.8
Exchanging the shaft seals . . . . . . . . . . . . . 22
5.9
Leybold service . . . . . . . . . . . . . . . . . . . . . . 24
6
Troubleshooting
. . . . . . . . . . . . . . . . . . . . 26
EEC Manufacturer’s Declaration . . . . . . . .29
Declaration of Conformity . . . . . . . . . . . . .31
Indicates procedures that must be strictly
observed to prevent hazards to persons.
Indicates procedures that must strictly be
observed to prevent damage to, or
destruction of the equipment.
Figures
The references to figures, e.g. (1/2) consist of the Fig.
No. and the Item No. in that order.
Leybold Service
If a pump is returned to Leybold, indicate whether the
pump free of substances damaging to health or whether
it is contaminated.
If it is contaminated also indicate the nature of the
hazard. Leybold must return any pumps without a
“Declaration of Contamination” to the sender’s address.
Disposal of waste oil
Under the amended law relating to waste disposal dated
November 1, 1986 (valid in the Federal Republic of
Germany) the disposal of used oil is subject to new
provisions. According to legislation relating to waste
disposal the so-called principle of causality is applied.
Hence, anyone in possession of used oil is responsible
for its proper disposal.
Used oils coming from vacuum pumps must not be
mixed with other substances.
Used oils from vacuum pumps (Leybold-oils on the basis
of mineral oils) having been affected by normal
contamination due to oxygen from the ambient air,
increases in temperature and mechanical wear, must be
disposed of as used oil in accordance with the
regulations.
Used oils from vacuum pumps that have been
contaminated by other substances must be labelled,
stored and disposed of as special waste with reference
to the kind of contamination.
When disposing of used oil please observe the safety
regulations that are valid in your country.
In many countries proof of were the oil has finally been
left is required by Law and often shipping of such
contaminated waste requires permission by the
authorities.
Waste disposal information is available through:
Bundesamt für Gewerbliche Wirtschaft (BAW)
Frankfurter Str. 29-31
D-65760 Eschborn/Taunus
Phone: +49 (0)6196 4041 – Telex: 415603/04
We reserve the right to modify the design and the
specified data. The illustrations are not binding.
2
Warning
Caution