20. Disconnect the frame wire.
(1)
Disconnect the 2 clamps and frame wire.
Clamp
21. Remove the No. 4 hybrid battery shield
panel.
Caution:
Wear insulated gloves for the following 2
steps.
(1) Using the service plug grip, remove
the battery cover lock striker
Hint:
Insert the projecting part of the service plug
grip and turn the button of the battery cover
lock striker counterclockwise to release the
lock.
(2) Remove the 3 bolts, 2 nuts and No. 4
hybrid battery shield panel
22. Disconnect the frame wire.
Caution:
Wear insulated gloves.
Notice:
Insulate the terminals of the removed
frame wire with insulating tape.
(1)
Remove the battery shield contact.
(2)
Remove the 2 nuts and disconnect the
frame wire
23. Remove the inverter terminal
Caution:
Wear insulated gloves.
Notice:
Insulate the terminals of the removed
frame wire with insulating tape.
(1)
Remove the nut and disconnect the frame
wire from the inverter terminal.