2-10
Service Manual
4400-001
Scanner Motor with Gear Assembly Service Check
Motor will not run.
FRU
Action
1
Scanner Motor with Gear
Assembly
Check scanner motor for shorts.
Disconnect connector CN8 from the
system board and check for
approximately 12.5 ohms between
the following pins on the motor
connector.
CN8-1 and CN8-2
If the ohms reading is incorrect,
replace the scanner motor assembly.
If the motor does not come on during
the scanning process, check
connector CN8 on the system board.
If the connection is okay, check for
voltage reading of approximately 28
volts at pins
CN8-1
CN8-2
CN8-3
CN8-4
If voltage is correct, replace the
scanner motor with gear assembly.
Go to the
“Scanner Motor with
Gear Assembly Removal” on
page 4-9
. If voltage is incorrect,
replace the system board. Go to the
“System Board Removal” on
page 4-21
.
2
Document Scanner Sensor
To check the document scanner
sensor, insert a sheet of paper or
depress the sensor to see if the
scanner motor is working. Go to
“Operator Panel Problems” on
page 2-3
.
Содержание X63
Страница 9: ...Safety Information ix 4400 001...
Страница 16: ...1 6 Service Manual 4400 001...
Страница 36: ...2 20 Service Manual 4400 001...
Страница 64: ...4 18 Service Manual 4400 001 11 Remove ASF assembly...
Страница 72: ...4 26 Service Manual 4400 001...
Страница 74: ...5 2 Service Manual 4400 001 Logic Card Units Description P1 System Board P2 Phone Lines...
Страница 75: ...Connector Locations 5 3 4400 001 Power Supply Units Description J5 System Board...
Страница 76: ...5 4 Service Manual 4400 001...
Страница 78: ...6 2 Service Manual 4400 001...
Страница 80: ...7 2 Service Manual 4400 001 Assembly 1 Main Assembly...
Страница 82: ...7 4 Service Manual 4400 001 Assembly 2 Base Unit...
Страница 84: ...7 6 Service Manual 4400 001 Assembly 3 Engine...
Страница 86: ...7 8 Service Manual 4400 001...