3-11
3.1.1.10
Ready and Power LED does not light on
Cause
Relevant Unit
Check Method
Maintenance
Method
Remark
ADF control board-
main control PCBA
connection failure
None
Visual check
Check connector
and the cable
between the ADF
control board and
main PCBA board.
None
ADF control board-
main control PCBA
cable failure
Sensor board-main
control PCBA cable
Tester or visual
check
★
Check ADF control
board.
◆
Home position
sensor board
failure
Sensor board
Tester check
★
Check PCBA main
board.
None
Power supply-main
control board
connection failure
None
Visual check
Connect the
connector.
None
Power supply fails
Power supply
Tester check
(+24V, GND)
★
Replace the power
supply.
None
Table 3.4
◆
= See section 1.5.3 Wiring configuration
★
= Refer to section 4.6
Содержание 3200 - MFP - Option
Страница 1: ...3200MFP Service Manual 4036 306 Lexmark International Inc...
Страница 4: ......
Страница 11: ...1 7 Wiring Configuration Figure 1 2 Wiring Configuration Control Panel Board CCD Board 2 LED Board CCD Board 1...
Страница 22: ......
Страница 45: ...4 5 4 3 3 Lamp Inverter circuit Figure 4 6 Lamp inverter circuit...
Страница 47: ...4 7 4 3 5 Motor unit Flatbed Figure 4 8 Motor unit Flatbed...
Страница 48: ...4 8 4 3 6 Belt Flatbed Figure 4 9 Belt Flatbed...
Страница 49: ...4 9 4 3 7 ADF unit Figure 4 10 ADF unit 4 3 8 Control Panel PCBA Figure 4 11 Control Panel PCBA...
Страница 69: ...5 1 5 PARTS 5 1 Spare Parts and AFR 4 1 7 8 5 3 2 9 10 6 10 1 11 12...
Страница 70: ...5 2 To Operator Panel 15 1 15 2 13 2 13 1 16 1 17 1 16 14 13 20 19 18 22 23 17 24 21 15...
Страница 71: ...5 3 D B C 2 C 1 Carton Pad Assembly Paper Output Chute Module A Scanner Main Body Assembly...
Страница 73: ...5 5...