3-2
3.1.1.1
Group 1 Error Flowchart
This flowchart applies when the flatbed lamp blinks seven or eight times. Seven blinks
indicate the lamp in the flatbed unit is defective while eight blinks indicate the lamp in the
ADF optical chassis is defective.
Flowchart 3.1
Group 1 error
Lamp is
on?
Inverter Error
Replace lamp
inverter circuit
CCD error
Replace optical
assembly
No
Yes
End of test
Replace the lamp
Lamp is on?
Yes
No