background image

MODEL:

STRATFORD SS38DV

LEXINGTON FORGE 

DIRECT VENT GAS STOVE

INSTALLATION AND OPERATING INSTRUCTIONS

 

WARNINGS

IF THE INFORMATION IN THESE INSTRUCTIONS ARE 
NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION 
MAY  RESULT  CAUSING  PROPERTY  DAMAGE, 
PERSONAL INJURY OR LOSS OF LIFE.

–    Do not store or use gasoline or other fl ammable 

vapors and liquids in the vicinity of this or any 
other appliance.

–    WHAT TO DO IF YOU SMELL GAS
      • Do not try to light any appliance.
      • Do not touch any electrical switch; do not use 

any phone in your building.

      • Immediately  call  your  gas  supplier  from  a 

neighbor's  phone.  Follow  the  gas  supplier's 
instructions.

      • If you cannot reach your gas supplier, call the 

fi re department.

–    Installation  and  service  must  be  performed 

by  a  qualifi ed  installer,  service  agency  or  the 
gas supplier.

WARNING:  Improper  installation,  adjustment, 
alteration, services or maintenance can cause injury or 
property damage. Refer to this manual. For assistance 
or additional information consult a qualifi ed installer, 
service agency or the gas supplier.   

This appliance is only for use with the type of gas 
indicated  on  the  rating  plate. This  appliance  is 
not  convertible  for  use  with  other  gases,  unless  a 
certifi ed kit is used. 
This appliance may be installed in an aftermarket*, 
permanently located, manufactured home, where not 
prohibited by local codes.

*Aftermarket: Completion of sale, not for purpose of resale, from 
the manufacturer. 

DUE TO  HIGH TEMPERATURES, THE 
APPLIANCE  SHOULD  BE  LOCATED 
OUT  OF TRAFFIC  AND  AWAY  FROM 
FURNITURE AND DRAPERIES.

CHILDREN  AND  ADULTS  SHOULD  BE 
ALERTED TO THE  HAZARDS  OF  HIGH 
SURFACE TEMPERATURE AND SHOULD 
STAY  AWAY  TO  AVOID  BURNS  OR 
CLOTHING IGNITION.

YOUNG  CHILDREN  SHOULD  BE 
SUPERVISED WHEN THEY  ARE  IN THE 
SAME ROOM AS THE APPLIANCE.

CLOTHING  OR  OTHER  FLAMMABLE 
MATERIAL  SHOULD  NOT  BE  PLACED 
ON OR NEAR THE APPLIANCE.

KEEP THE  ROOM  AREA  CLEAR  AND 
FREE FROM COMBUSTIBLE MATERIALS, 
GASOLINE,  AND  OTHER  FLAMMABLE 
VAPORS AND LIQUIDS.

READ BEFORE INSTALLING. SAVE THESE INSTRUCTIONS

Содержание STRATFORD SS38DV

Страница 1: ...age Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier This appliance is only for use with the type of gas indicated on the...

Страница 2: ...25 Operating Instructions 29 What To Do If You Smell Gas 29 Lighting Pilot for the First Time 29 Lighting Pilot 30 Lighting Burner 30 To Turn Off Gas 31 Maintenance 32 Venting System 32 Cleaning Glass...

Страница 3: ...d If this unit is not properly installed by a qualified service person with glass door properly seated and sealed combustion leakage can occur CARBON MONOXIDE POISONING Early signs of carbon monoxide...

Страница 4: ...nings into the combustion chamber along with adequate accessibility clearance for servicing and proper operation 17 When the appliance is installed directly on carpeting tile or other combustible mate...

Страница 5: ...onnected to a venting system The appliance is not approved for closet or recessed installations For alcove installation see Clearances page 8 Hi Lo Knob PRODUCT SPECIFICATIONS The efficiency rating of...

Страница 6: ...Supply Pressure 11 SS38 A 261 2 B 17 C 311 2 D 331 2 Figure 2 External Stove Dimensions STOVE DIMENSIONS NOTE If this unit is installed in a mobile home it must be bolted securely to the floor with le...

Страница 7: ...fort centrally locate the stove in a large and open room The flow of combustion and ventilation air must not be obstructed Minimum clearances to combustibles side wall ceiling woodwork and windows mus...

Страница 8: ...r vinyl flooring the appliance shall be installed on a metal wood or noncombustible material panel extending full width and depth of the appliance WARNING CLEARANCES Figure 4 Clearances to Side Back a...

Страница 9: ...ction Use extreme caution when using ladders or when on rooftops Be aware of electrical wiring locations in walls and ceilings The following actions will void the warranty on your venting system Insta...

Страница 10: ...5 elbows up to a maximum of 270 For two story applications firestops are required at each floor level If an offset is needed in the attic additional pipe and elbows will be required You may use a chas...

Страница 11: ...e to unventilated soffits 12 305mm minimum Clearance to vinyl soffit 30 762mm F Clearance to an outside corner See page 12 G Clearance to an inside corner See page 12 H Not to be installed above a gas...

Страница 12: ...D0232 VENT INSTALLATION TERMINATION CLEARANCES FOR BUILDINGS WITH COMBUSTIBLE AND NONCOMBUSTIBLE EXTERIORS Figure 7 Allowable Venting Chart NOTE Any vent configurations with the shaded areas are accep...

Страница 13: ...ure 9 Do not back fill around the snorkel termination 2 Rigid vent pipes and fittings have special twist lock con nections Assemble the desired combination of pipe and elbows to the appliance adaptor...

Страница 14: ...bles is maintained Attach the vent cap with four wood screws supplied See Figure 12 Do not recess vent termination into any wall This will cause a fire hazard WARNING For vinyl siding stucco or wood e...

Страница 15: ...ONTAL VENT INSTALLATION CONTINUED Interior Wall Surface Decorative Wall Thimble Horizontal Vent Pipe Screw Vent Cap Horizontal Termination HORIZONTAL TERMINATION CONFIGURATIONS Figures 15 through 17 s...

Страница 16: ...r Rigid Venting Using Two 90 Elbows Horizontal H Vertical V V1 Horizontal H1 5 minimum 4 maximum 6 minimum 6 maximum 8 minimum 10 maximum 20 maximum 12 maximum VENTING WITH THREE 90 ELBOWS Figure 17 H...

Страница 17: ...d to 91 2 x91 2 241mm x 241mm inside dimensions as shown in Figure 20 using framing lumber the same size as the ceiling joist If the area above the ceiling is an insulated ceiling or a room nail fires...

Страница 18: ...ure 21 Cathedral Ceiling Support Box Installation Figure 22 Installed Cathedral Ceiling Support Box CATHEDRAL CEILING INSTALLATION IMPORTANT Review all information on previous page before planning thi...

Страница 19: ...imum 2 maximum 9 minimum 4 maximum 10 minimum 6 maximum 11 minimum 8 maximum 23 maximum 8 maximum Figure 24 Vertical Rigid Venting Configuration Using Three 90 Elbows with Two Horizontal Runs Vertical...

Страница 20: ...nt vent section as shown NUMBER DESCRIPTION NUMBER DESCRIPTION 902B 7 x 48 Pipe 943S Roof Flashing 7 12 12 12 903B 7 x 36 Pipe 945B 7 x 45 Elbow 904B 7 x 24 Pipe 950 Vinyl siding Standoff 906B 7 x 12...

Страница 21: ...e to gas supply Follow all local codes WARNING INSTALLATION ITEMS NEEDED Before installing stove and burner system make sure you have the items listed below External regulator supplied by installer Pi...

Страница 22: ...in supply line as shown in Figure 28 Locate sediment trap drip leg where it is within reach for cleaning Install in piping system between fuel supply and burner system Locate sediment trap drip leg w...

Страница 23: ...HI to get maximum pressure to burner Turn HI LO knob to LO to get minimum pressure 5 To check gas pressures at valve turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressu...

Страница 24: ...NSTALLATION ELECTRICAL WIRING Electrical connections should only be performed by a qualified licensed electrician Main power must be off when connecting to main electrical power supply or performing s...

Страница 25: ...After handling the logs wash your hands gently with soap and water to remove any traces of fibers The positioning of the logs is critical to the safe and clean operation of this heater Sooting and oth...

Страница 26: ...See Figure 34 6 Place top left log on left base log Line up the hole in the bottom of the top log with the locating pins on the bottom log See Figure 35 LOG PLACEMENT Figure 34 Installing Right Base...

Страница 27: ...Right Log Top Center Log LOG PLACEMENT 7 Place top right log on right base log Line up the holes in the bottom of the top log with the locating pins on the bottom log See Figure 36 8 Place top center...

Страница 28: ...d Rock Wool Rock Wool Figure 38 Installing Rock Wool Embers 9 Break up rock wool ember material into dime sized pieces Place evenly across burner surface and mesh of grate See Figures 38 and 39 Do not...

Страница 29: ...lt in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service tech nician to inspect the appliance and to replace any part of the co...

Страница 30: ...he magnet is closed it is possible to start the lighting operation The gas control knob is designed to be operated by hand DO NOT use any tools during this operation Damaged knobs may result in seriou...

Страница 31: ...rn off the main burner without using the gas valve knob Make sure the button is in the ON position to light the main burner See Figure 41 LIGHTING THE BURNER Depress and turn the knob counterclockwise...

Страница 32: ...re 46 for typi cal pilot flame Let glass cool before cleaning Do not clean glass when it is hot Damage could occur CAUTION Make sure the gas valve knob is in the OFF position Wait at least five 5 minu...

Страница 33: ...or high altitude as follows To increase air mixture push up the adjustment rod located beneath the stove This opens the shutter more and will stop or minimize sooting See Figure 47 To decrease air mix...

Страница 34: ...ece glass style frame slide new glass into the 45 aluminum post not shown 7 Fasten retaining brackets back into place with 5 16 nuts 8 Replace 7 8 rope Make sure the joint is at the bottom and there i...

Страница 35: ...46D0232 35 BLOWER BLOWER WIRING DIAGRAM FOR BLOWER...

Страница 36: ...36 46D0232 REPLACEMENT PARTS...

Страница 37: ...Shutter Rod 1 46D0211 46D0211 46D0211 46D0211 12 Air Shutter Knob 1 45D0237 45D0237 45D0237 45D0237 13 Knob Extension HI LO 1 43D0095 43D0095 43D0095 43D0095 14 Knob Extension ON OFF 1 43D0094 43D009...

Страница 38: ...fromtheelectrode to pilot Adjust by loosening screws on pilot base Adjust and retighten 4 Replace with new wire 1 A Check for proper connection of ther mocouple to rear of valve B Check thermocouple o...

Страница 39: ...THE INSTALLER FOR WARRANTY PURPOSES AND FUTURE REFERENCE LEXINGTON FORGE Model _____________________________ Name of Owner Name of Installer Address Address Phone Phone Name of Dealer Address Phone M...

Страница 40: ...ve finished grade in the area of the venting including but not limited to decks and porches the following requirements shall be satisfied 1 INSTALLATION OF CARBON MONOXIDE DETECTORS At the time of ins...

Страница 41: ...d in whole or in part for residential purposes c MANUFACTURER REQUIREMENTS GAS EQUIPMENT VENTING SYSTEM PROVIDED When the manu facturer of Product Approved side wall horizontally vented gas equipment...

Страница 42: ...or authorized service center shipping damage damage from improper use or neglect installation damage damage from unauthorized service incidental or consequential damage or negative pressure caused by...

Отзывы: