Lexington Forge SAVANNAHSSW40 Скачать руководство пользователя страница 5

63D4002 

5

PRE-INSTALLATION INSTRUCTIONS

BEFORE INSTALLATION OF YOUR APPLIANCE

1.  Check with the building inspector’s office for compliance with local codes; a permit may be required.

2.  This appliance requires a masonry or prefabricated chimney listed to ULC S629 (Canada) and UL 

103HT (U.S.) sized correctly.

3.  A 6

"

 (152mm) diameter flue is required for proper performance.

4.  Always connect this unit to a chimney and 

NEVER

 VENT TO ANOTHER ROOM OR INSIDE A 

BUILDING.

5.  DO NOT 

connect this unit to any duct work to which another appliance is connected such as a 

furnace.

6.  DO NOT

 connect this unit to a chimney flue serving another appliance.

7.   

The connector pipe and chimney should be inspected periodically and cleaned if nescessary.

8.  Remember the clearance distances when you place furniture or other objects within the area.  

DO 

NOT

 store wood, flammable liquids or other combustible materials too close to the unit.  

Refer to 

certification label on back of your unit for required clearances.

9.  Contact your local municipal or provincial fire authority for information on how to handle a chimney 

fire.  Have a clearly understood plan to handle a chimney fire.  In the event of a chimney fire, turn air 

control to closed position and 

CALL THE FIRE DEPARTMENT.

10. DO NOT 

tamper with combustion air control beyond normal adjustment.

11.  If installing in a mobile home, use mobile home kit.

WHY THE CORRECT FLUE SIZE IS IMPORTANT — 6

"

 (152 mm)

Draft is the force, which moves air from the appliance up through the chimney.  The amount of draft in 

your chimney depends on the length of the chimney, local geography, nearby obstructions, and other 

factors.  Too much draft may cause excessive temperatures in the appliance.  An uncontrolled burn, 

a glowing red part or chimney connector indicates excessive draft.  Inadequate draft may cause back 

puffing into the room and “plugging” of the chimney and/or cause the appliance to leak smoke into the 

room through appliance and chimney connector joints.
Today’s solid fuel appliances are much more efficient than in the past.  The units are designed to give 

you controlled combustion, as well as maximum heat transfer, using less fuel to do so. The design of your 

new appliance is such that the exhaust “smoke” is now at lower temperatures than in the past, therefore 

requiring proper chimney size to give adequate draft.  If your chimney is too large, the heating appliance 

will have a difficult time to raise the “chimney flue” temperature to give adequate draft, therefore causing a 

smoke back up, poor burn, or both.

Should you experience such a problem call in a local chimney expert.

With the door closed, the rate of burning is regulated by the amount of air allowed to enter the unit 

through the air control.  With experience you will be able to set the control for heat and burning time 

desired.

Once the required chimney draft is obtained, operate only with doors closed and open slowly when re-

fueling.  (This will reduce or eliminate smoke from entering the room.)

CAUTION

After reading these instructions, if you have any doubt about your ability to complete 
your installation in a professional manner, you should obtain the services of an installer 
versed in all aspects of correct and safe installation.  

DO NOT

 use temporary, makeshift 

compromises during installation.

Содержание SAVANNAHSSW40

Страница 1: ...uctions may result in property damage bodily injury or even death Contact local building fire officials or authorities having jurisdiction about permits restrictions and instal lation inspection requirements in your area These units are mobile home approved for U S and Canada SAVANNAH LARGE WOOD STOVE FOR RESIDENTIAL INSTALLATION 6 152 mm Flue Required OWNERS MANUAL MODEL SSW40 6300002 SSW40 cover...

Страница 2: ...uctive harm California Health and Safety Code Sec 25249 6 WARNING ACCESSORIES 1 Variable Speed Blower Part no BLOTWS 2 Gold Legs Part no SSW30CLGD 3 Gold Door Trim Part no SSW30GDTK 4 Nickel Legs Part no SSW30CLN 5 Nickel Door Trim Part no SSW30NDTK Operation 12 Maintenance 15 Replacement parts 18 Illustrated Parts Breakdown 19 FAQs 20 Warranty 23 IMPORTANT Read these instructions carefully before...

Страница 3: ...63D4002 A B C D E F 634002 SSW40 DIMS 10 08 SPECIFICATIONS MODEL A B C D E F SSW40 331 4 311 2 23 32 261 2 273 4 OVERALL DIMENSIONS SSW40 Front and Side Views ...

Страница 4: ... live in a more severe and more temperate climate these figures may not apply Since so many variables affect performance consult your Lexington Forge Authorized Dealer to determine realistic expectations for your home 3 Under specific conditions used during EPA emissions testing Need to ask questions Require Parts Information First contact the Lexington Forge Dealer from whom you purchased your st...

Страница 5: ...pends on the length of the chimney local geography nearby obstructions and other factors Too much draft may cause excessive temperatures in the appliance An uncontrolled burn a glowing red part or chimney connector indicates excessive draft Inadequate draft may cause back puffing into the room and plugging of the chimney and or cause the appliance to leak smoke into the room through appliance and ...

Страница 6: ... heater performance at low burn rate operate the fan at low speed An outside air kit is available from your Lexington Forge dealer Optional Blower 110v 130 CFM Model BLOTWS OPERATE THIS HEATER ONLY WITH THE DOOR CLOSED DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE CAUTION THIS HEATER IS EXTREMELY HOT WHILE IN OPERATION SERIOUS BURNS CAN RESULT FROM CONTAC...

Страница 7: ...l liner may be required 6 It is recommended that no more than two 90 degree bends be used in the stovepipe installation More than two 90 degree bends may decrease the amount of draw and possible cause smoke spillage 7 A damper is not required in this installation Remove any damper plate in the chimney or secure in the OPEN position 8 Single wall flue pipe assemblies must not exceed 10 feet 3 meter...

Страница 8: ...in total mass the longer it will take to warm up Cold masonry will actually cool exhaust gases enough to diminish draft strength This problem is worse if the chimney is located outside the home or if the chimney flue has a cross sectional volume much larger than the stove outlet Pipe and Chimney Layout Every bend in the flue will act as a brake on the exhaust as it flows from the firebox to the ch...

Страница 9: ...s to Combustibles UL 1482 and ULC s627 Minimum clearances to combustible materials in inches Note All A C and F dimensions are to the stove pipe A B C D E F G H I Installation Full Vertical Single Wall Pipe Flat top model 15 10 26 15 8 20 50 18 8 Double Wall Pipe Flat top model 13 8 23 12 Figure 1 Clearances to Combustibles ST1008 ...

Страница 10: ...to close up the opening must be non combustible The following wall pass through methods may be approved in your area Use a section of listed factory built chimney with a nine inch clearance to combustibles Place a chimney connector pipe inside a ventilated thimble which is then separated from combustibles by 6 152 mm of fiberglass insulating material Place a chimney connector pipe inside a section...

Страница 11: ...ally designed as a unit for use as fireplaces It may void the listing or be hazardous to adapt them for any other use Floor Protector Installation on a Concrete Floor An appliance mounted on a concrete floor does not require floor protection Carpeting and any other combustible material shall not cover the floor protector If a combustible surface is applied to the concrete floor a clearance must be...

Страница 12: ... months during the heating season to determine if a buildup of creosote or soot has occurred If a significant layer of creosote has accumulated 1 8 3 mm or more or if soot has accumulated either should be removed to reduce the risk of a chimney fire Failure to keep the chimney and connector system clean can result in a serious chimney fire The conditions for a chimney fire develop as follows When ...

Страница 13: ...sture before the wood can burn This significantly reduces the amount of energy available to warm your home as well as the intensity of the fire and temperature of the exhaust gas Incomplete combustion and cool flue temperatures promote creosote formation and weak draft You can judge the moisture content of wood by its appearance and weight or use a commercially available moisture meter for exact m...

Страница 14: ...to cure before burning for long periods at high temperatures 3 Flat spots on the painted surfaces are normal 4 Shiny spots on the paint surface before burning is normal 5 Call your dealer if you have any questions BUILDING A FIRE 1 Open inlet air control fully 2 Place a small amount of crumpled paper in the stove 3 Cover the paper with a generous amount of kindling wood in a teepee fashion and a f...

Страница 15: ...down into the firebox until it can be removed through the door opening You can now remove the rear piece the same way Figures 8 and 9 6 Replace the C cast baffle and tubes After the tubes are in place check to see that the c cast baffle is slid back against the steel non removable baffle Replace the rear bricks Cleaning your chimney The Savannah SSW40 stove has a removable baffle which allows the ...

Страница 16: ...seal periodically to ensure proper seal if gaskets become frayed or worn replace immediately Contact your Lexington Forge dealer for approved replacement parts Refer to replacement parts list in this manual The following steps should be followed for glass gasket replacement 1 Ensure appliance is not in operation and is thoroughly cooled 2 Remove door and place on a protected flat surface 3 Remove ...

Страница 17: ...d burns wood vapors which might otherwise be deposited within the systems 3 BURN ONLY SEASONED WOOD Avoid burning wet or green wood Seasoned wood has been dried for at least one year 4 A small hot fire is preferable to a large smoldering one that can deposit creosote within the system 5 Establish a routine for the fuel wood burner and firing technique Check daily for creosote build up until experi...

Страница 18: ...18 63D4002 4 1 2 3 5 6 20 7 18 19 16 10 11 12 13 14 15 17 9 8 634002 SSW40 parts 10 08 illustrated parts breakdown Figure 9 Exploded View ...

Страница 19: ...3D0188 8 1 Fettle 63D3002 9 1 Airwash Cast Iron 63D3001 10 1 Shroud Left 63D3117 11 1 Tube Secondary Air Top 63D3006 12 4 Tube Secondary Air Bottom 63D3007 13 1 C Cast Combo Bottom 63D3008 14 1 C Cast Top Dead Air 63D3005 15 1 Shroud Rear 63D0008 16 1 Shroud Right 63D3118 17 23 Brick Paver 63D0162 18 4 Leg Cast Iron 63D0186 19 1 Ash Pan Drawer 63D3159 20 1 Air Adjustment Assembly 63D3071 21 1 Full...

Страница 20: ... good combustion is now possible Larger pieces of seasoned dry firewood can now be added when there is sufficient space in the firebox Adjust the air control setting to desired setting see page 14 i Note The lower the air control setting the longer the burn time of your firewood 2 What type of wood is best to use as firewood Dry seasoned hardwood should be used Avoid green unseasoned wood Green wo...

Страница 21: ...ased amounts of insulation vinyl windows extra caulking in various places and door seals can all keep heat in but may also make a home too airtight If you are in doubt about whether or not there is sufficient air in your home for your stove curtail from using those appliances known to consume the air where possible or open a window or door to allow air to enter the home b Environmental Conditions ...

Страница 22: ...22 63D4002 NOTES ...

Страница 23: ...will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage by over firing over loading accident neglect misuse abuse alteration negligence of others including the installation thereof by unqualified install ers 2 the costs of removal reinstallation or transportation of...

Страница 24: ...24 63D4002 OCTOBER 2008 63D4002 Rev 1 MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com ...

Отзывы: