HOT
�
�
�
�
�
�
Horizontal (H) +
Vertical (V)
Horizontal (H)
Horizontal (H
1
)
5' minimum
4' maximum
8' maximum
6' minimum
6' maximum
12' maximum
7' minimum
8' minimum
20' maximum
20' maximum
8' maximum
20' maximum
VENT INSTALLATION
VENTING WITH TWO 90° ELBOWS
Figure 16 - Horizontal Termination
Configuration for Rigid Venting Using
Two 90° Elbows
Horizontal (H) +
Vertical (V) + (V
1
)
Horizontal (H
1
)
5' minimum
4' maximum
6' minimum
6' maximum
8' minimum
10' maximum
20' maximum
12' maximum
VENTING WITH THREE 90° ELBOWS
Figure 17 - Horizontal Termination Configuration
for Rigid Venting Using Three 90° Elbows with
Termination at 90° with Stove
NOTE: Add
1
/
4
" rise per 12"
horizontal length of pipe.
NOTE: Add
1
/
4
" rise per 12" horizontal
length of pipe.
Table 2 - Venting with Two 90° Elbows
Table 3 - Venting with Three 90° Elbows