background image

Warning!

Please confirm with profession installation.
Please cut off power supply before installation and removal operations.
Make sure that you have cut off the power for safety purposes.
Improper operation caused losses, the manufacturer does not undertake any responsibility.

Troubleshooting

 

Malfunction

 

Cause

 

Remedy

 

·

wrong light-control setting selected 

·

Adjust setting 

·

load faulty 

·

Change load 

The load will not work 

·

mains switch OFF 

·

Switch ON 

The load work always 

·

continuous movement in the detection 

zone 

·

Check zone setting 

·

the  sensor  not  mounted  for  detecting 

movement reliably 

·

Securely mount enclosure 

The  load  work  without  any 
identifiable movement 

·

movement  occurred,  but  not  identified 

by  the  sensor(movement  behind  wall, 
movement of a small object in immediate 
lamp vicinity etc.) 

·

Check zone setting 

The  load  will  not  work  despite 
movement 

·

rapid movements are being suppressed 

to minimize malfunctioning

the 

 zone you have set is too  small

 

·

Check zone setting 

detection

or 

Note: please don’t adjust the three functional buttons to excess. That is because the 
three functional buttons were connected to the components directly, there is a small 
stopper in each of the three components, when you adjust the buttons from start to end, 
the excessive turn will damage the stopper

and lead to the 360°non-stop turn around. 

The adjust range limit is 270°, please do pay attention to this.

www.lexing.com.cn

Содержание LX-MV-360S1

Страница 1: ...ction way has the below advantages compared with other as follows 1 Non contact detection 2 Suitable for bad environment immune to temperature humidity noise air dust light 3 RF interference ability 4 Transmission power only 0 2 mW It will not harm the human body Simple installation easy wiring We use appropriative micro processing integrator not only for high sensitivity and wide range of detecti...

Страница 2: ...ase against the Ceiling and mark drill holes see fig 3 paying attention to any existing wiring in the Ceiling 3 Drill the holes insert wall plugs 6mm dia see fig 4 4 Put the power wire and load wire through the base holes see fig 5 5 Screw the base into place see fig 6 6 Connect the mains power supply and the load wire to the connection terminal according to connection wire mark 7 Close the middle...

Страница 3: ...also change NOTE after the light switches OFF it takes approx 1sec before it is able to start detecting movement again The light will only switch on in response to movement once this period has elapsed Light control setting The chosen light response threshold can be infinitely from approx 2 2000lux Turn it fully anti clockwise to select dusk to dawn operation at about 2 lux Turn it fully clockwise...

Страница 4: ...nclosure The load work without any identifiable movement movement occurred but not identified by the sensor movement behind wall movement of a small object in immediate lamp vicinity etc Check zone setting The load will not work despite movement rapid movements are being suppressed to minimize malfunctioning the zone you have set is too small Check zone setting detection or Note please don t adjus...

Отзывы: