Warning!
Please confirm with profession installation.
Please cut off power supply before installation and removal operations.
Make sure that you have cut off the power for safety purposes.
Improper operation caused losses, the manufacturer does not undertake any responsibility.
Troubleshooting
Malfunction
Cause
Remedy
·
wrong light-control setting selected
·
Adjust setting
·
load faulty
·
Change load
The load will not work
·
mains switch OFF
·
Switch ON
The load work always
·
continuous movement in the detection
zone
·
Check zone setting
·
the sensor not mounted for detecting
movement reliably
·
Securely mount enclosure
The load work without any
identifiable movement
·
movement occurred, but not identified
by the sensor(movement behind wall,
movement of a small object in immediate
lamp vicinity etc.)
·
Check zone setting
The load will not work despite
movement
·
rapid movements are being suppressed
to minimize malfunctioning
the
zone you have set is too small
·
Check zone setting
detection
or
Note: please don’t adjust the three functional buttons to excess. That is because the
three functional buttons were connected to the components directly, there is a small
stopper in each of the three components, when you adjust the buttons from start to end,
the excessive turn will damage the stopper
,
and lead to the 360°non-stop turn around.
The adjust range limit is 270°, please do pay attention to this.
www.lexing.com.cn