30
Lexicon
Customization
Customization
Locking In Settings
After you have calibrated and customized the CP-3
PLUS
, there are two
additional steps recommended to safeguard the settings:
First, document your adjustments on the Installation Worksheet (provided
at the end of this manual) if you have not already done so.
Second, consider locking the settings in so that they cannot be inadvertently
changed. Locking the settings will allow full operation with the Standard
remote, but will limit the Expanded remote’s ability to change operating
parameters. Specifically, with the Settings Lock ON, the Expanded remote
will function normally but will not be able to change values in the Setup
menu or any parameters. The PARAM button will function normally, so
the parameters can be selected, but pressing either PARAM
▲
or
▼
will
simply display the parameter value and yield a "SETTINGS ARE LOCKED"
message.
To lock the settings, press SETUP and select "LOCK SETTINGS".
With LOCK SETTINGS selected, press PARAM
▲
twice to select the Lock
Settings parameter and engage it. To turn the lock off, follow the same
procedure but press the PARAM
▼
button instead of PARAM
▲
until the
display reads:
SETTINGS LOCK
OFF
When the CP-3
PLUS
is first turned on, it will display a copyright notice with
the current software version. The next screen will say:
CUSTOMIZED FOR
DEMONSTRATION
The word "demonstration" can be replaced with the owner's name (up to 16
characters). The name assigned here can only be changed with the following
procedure. It will not be deleted even when the Restore Defaults procedure
(see Chapter 4) is performed.
To do this call up the Setting menu as described above and move the cursor
to select "CUSTOM NAME". Press PARAM
▲
, then press BANK to unlock
the custom name. The PARAM button will now move the cursor to one of
16 available spaces in the display, while PARAM
▲
and
▼
cycle through the
available list of characters, beginning with the one currently occupying the
space.
Custom Name