3.
Important Safety Information
This Equipment must only be installed and maintained by a suitably skilled and competent person.
This Equipment is defined as Class 1 in EN60065 (Low Voltage Directive) and must be EARTHED.
Caution
Indoor Use Only
Warning
Shock Hazard-
Isolate Before Opening
Warning
TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK, DO NOT EXPOSE THIS UNIT TO RAIN
OR MOISTURE
Warning
THIS UNIT MUST BE EARTHED
Warning
NO USER SERVICEABLE PARTS
Each ViLX-228 Master/Repeater Station requires a 3A spur, returning to a breaker clearly marked “EVCS
DO NOT TURN OFF”.
If the ViLX-228 Master Station and the ViLX-228 Repeater Station are distributed around a site, it is
essential that both ViLX-228 Stations are on the same mains phase, as they are classified TEN 230V.
Powering from different phases can mean a 440V potential can be present in a ViLX-228 Station during
a major fault incident.
Anti-static handling guidelines
Make sure that electrostatic handling precautions are taken immediately before handling PCBs and other
static sensitive components.
Before handling any static-sensitive items, operators should get rid of any electrostatic charge by
touching a sound safety earth. Always handle PCBs by their sides and avoid touching any components.