Two TOPAZ "Rack" control modules are provided for each rack connected to a common set of terminals. These control
modules are located in the two slots directly under the last dimmer module slot.
•
Connect the control wires to the 20-pin terminal block (TB4) in each rack. Refer to Figure 6.
Figure 7- Stage Control Terminations
(
Optional)
Figure 6 – Stage Control Terminations
FROM CONSOLE, DLR INTERFACE OR PREVIOUS RACK
Step 10 - Seal unused openings
•
Seal any unused mounting and conduit access holes in the rack. If conduits are large and relatively empty or
if they connect to a gutter nearby, they must be sealed as well. Verify that the bottom conduit access panel is
installed.
This is necessary to maintain proper ventilation while the rack is operating.