DMX-512 multiplex control wiring.

DMX 512 is the United States Institute of Theater Technology (USITT) standard for the digital control of dimmers. NSI DDS relay
products can be converted from Microplex to DMX 512 digital multiplex with a simple kit available from your dealer. 

DMX-512 is the preferred type of control wiring when many relay or pack channels are used, because of the high update rate and
the resistance to interference. It is recommended in locations subject to electrical noise. DMX-512 only requires 3 wires to transmit
lighting  levels for as many as 512 relay or dimmer channels.  Most of the NSI  lighting control consoles can optionally use this
interface.

Connect the DMX 512 cable from the control console to the male input connector.  Another cable may  be connected from the
female connector to the male connector on another pack.  Many relay packs may be "daisy chained" or connected together in this
manner. 

Be sure to set the Channel Address dipswitch as required (see DIPSWITCH SETTINGS).

LED INDICATORS

The front panel indicator LEDs indicate the status of the relay.

RED - Indicates the firing card is receiving DC power. 

GREEN - Steady indicates a multiplex control signal is being received. 

YELLOW - Indicates a respective relay channel is active.

AUTO LAMP TEST

Whenever dipswitch #8 is in the off (down) position and there is no multiplex signal detected, all channel outputs will come to full
intensity.  

CHANNEL FUSES

Each channel is protected by a fuse to help prevent overload and damage to the power control devices used in the relay.  Be sure
to replace the fuse with the same type and rating.  Replacement with the wrong fuse is dangerous and will void your warranty.   

Note:  Lamps may sometimes cause a temporary "short-circuit" when the filament burns out and cause the fuse to blow.
This is normal and protects the internal relay circuitry from damage.

 INSTALLATION  and OPERATION TIPS

Care should always be taken to:

1) Keep all AC wiring away from control wiring.

2) We also recommend power up and performance checks be done one unit at a time. This can be a real time saver should problems
arise thus eliminating unnecessary isolation techniques to resolve problems.

DDS 3600R RELAY PACK

DMX-512 multiplex control wiring.

Software Revision 1.0, Version C UL Versions

4

NSI CORPORATION

Содержание DDS3600R

Страница 1: ... per channel Input Voltage DDR 3600 15 120 VAC 1800 Watts Max DDR 3600 20 120 VAC 2400 Watts Max Control system Microprocessor digital zero crossing relay mode Control Input Types 0 10VDC each channel on 5 pin DIN connector switchpoint on 2V off 75V MICROPLEX multiplex signal 128 channel on three pin XLR type connector 20 switchpoint DMX 512 digital signal 512 channel on five pin XLR optional 20 s...

Страница 2: ...nnected to a power source capable of supplying the total power drawn by the lights See specifications for details on maximum power capability WARNING Do not remove grounding prong of AC plug To do so may allow exposure to potentially lethal voltage levels and will void the warranty on this product AC OUTPUT RECEPTACLES The DDS 3600R has one AC receptacle for each channel These receptacles provide ...

Страница 3: ...NGS ANALOG 0 10 VDC CONTROL WIRING Each of the four relay channels of the DDS 3600R may be operated by an analog 0 10 VDC control voltage This type of control will provide 0 intensity at less then 1 volt and 100 intensity at greater than 2 volts to a maximum of 10 volts Any or all of the DDS 3600R relay channels may be operated in this manner simultaneously with any multiplex control input Each re...

Страница 4: ... LEDs indicate the status of the relay RED Indicates the firing card is receiving DC power GREEN Steady indicates a multiplex control signal is being received YELLOW Indicates a respective relay channel is active AUTO LAMP TEST Whenever dipswitch 8 is in the off down position and there is no multiplex signal detected all channel outputs will come to full intensity CHANNEL FUSES Each channel is pro...

Страница 5: ...1100110 209 212 0010110 213 216 1010110 217 220 0110110 221 224 1110110 225 228 0001110 229 232 1001110 233 236 0101110 237 240 1101110 241 244 0011110 245 248 1011110 249 252 0111110 253 256 1111110 257 260 0000001 261 264 1000001 265 268 0100001 269 272 1100001 273 276 0010001 277 280 1010001 281 284 0110001 285 288 1110001 289 292 0001001 293 296 1001001 297 300 0101001 301 304 1101001 305 308 ...

Страница 6: ...SERVICE INFORMATION DDS 3600R RELAY PACK SERVICE INFORMATION Software Revision 1 0 Version C UL Versions 6 NSI CORPORATION ...

Страница 7: ...epair or replace at its option defective materials provided you have identified yourself as the original owner of the product to NSI or any authorized NSI dealer Transportation charges to and from an authorized dealer or the NSI factory for repair shall be the responsibility of the owner All products returned to NSI must have factory authorization for return prior to shipping NSI Corporation is no...

Отзывы: