MOUNTING

The NSI DDS 3600R relay packs are designed to be mounted vertically.  Each pack pack is provided with a reversible hangar
bracket that can be hung on up to 1 15/16" tubing, or may accept a pipe clamp.  BE SURE TO USE A SAFETY CABLE TO
PREVENT INJURY IF PACK FALLS.

Since the DDS 3600R depends upon convection cooling, room air flow must be insured.  Keep the air vents located on each side
of the pack pack clear of dust or any obstructions. In order for unit to cool properly the surface containing the control receptacles
must be orientated towards the floor.

If several units are to be operated in a small enclosed room, adequate ventilation must be provided to prevent the room temperature
from exceeding 100 degrees Fahrenheit

AC POWER CABLE.

This is the main power cord for your relay pack which ultimately carries all of the ac power consumed by lights connected to the
relay pack. The DDS 3600R with the NEMA 5-15 plug is limited to 1800 watts max., while the unit with the NEMA 5-20 plug
will support the full 2400 watts. It must be connected to a power source capable of supplying  the total power drawn by the lights.
(See specifications for details on maximum power capability.)

WARNING:  Do not remove grounding prong of AC plug.  To do so may allow exposure to potentially lethal voltage levels
and will void the warranty on this product. 

AC OUTPUT RECEPTACLES

The DDS 3600R has one AC receptacle for each channel.  These receptacles provide power to the lamps in your lighting system.
The amount of power supplied to these outlets controls the operation of the lamps connected.  

The total lamp wattage connected to each channel must not exceed the rating of each channel (see specifications).  Most 120VAC
lamps and fixtures and some transformer type low-voltage fixtures may be connected to these outlets.

NOTE:  Some inductive type loads such as transformers, ballasts, and motors with poor power factor may cause the relay
to output D.C. type current.  This may cause the load to draw excessive current and overheat,  causing damage to the
transformer, ballast, or motor.  For this reason, it is necessary to insure any inductive loads are fused individually  for their
respective normal operating current.

DDS 3600R RELAY PACK

MOUNTING

Software Revision 1.0, Version C UL Versions

2

NSI CORPORATION

Содержание DDS3600R

Страница 1: ... per channel Input Voltage DDR 3600 15 120 VAC 1800 Watts Max DDR 3600 20 120 VAC 2400 Watts Max Control system Microprocessor digital zero crossing relay mode Control Input Types 0 10VDC each channel on 5 pin DIN connector switchpoint on 2V off 75V MICROPLEX multiplex signal 128 channel on three pin XLR type connector 20 switchpoint DMX 512 digital signal 512 channel on five pin XLR optional 20 s...

Страница 2: ...nnected to a power source capable of supplying the total power drawn by the lights See specifications for details on maximum power capability WARNING Do not remove grounding prong of AC plug To do so may allow exposure to potentially lethal voltage levels and will void the warranty on this product AC OUTPUT RECEPTACLES The DDS 3600R has one AC receptacle for each channel These receptacles provide ...

Страница 3: ...NGS ANALOG 0 10 VDC CONTROL WIRING Each of the four relay channels of the DDS 3600R may be operated by an analog 0 10 VDC control voltage This type of control will provide 0 intensity at less then 1 volt and 100 intensity at greater than 2 volts to a maximum of 10 volts Any or all of the DDS 3600R relay channels may be operated in this manner simultaneously with any multiplex control input Each re...

Страница 4: ... LEDs indicate the status of the relay RED Indicates the firing card is receiving DC power GREEN Steady indicates a multiplex control signal is being received YELLOW Indicates a respective relay channel is active AUTO LAMP TEST Whenever dipswitch 8 is in the off down position and there is no multiplex signal detected all channel outputs will come to full intensity CHANNEL FUSES Each channel is pro...

Страница 5: ...1100110 209 212 0010110 213 216 1010110 217 220 0110110 221 224 1110110 225 228 0001110 229 232 1001110 233 236 0101110 237 240 1101110 241 244 0011110 245 248 1011110 249 252 0111110 253 256 1111110 257 260 0000001 261 264 1000001 265 268 0100001 269 272 1100001 273 276 0010001 277 280 1010001 281 284 0110001 285 288 1110001 289 292 0001001 293 296 1001001 297 300 0101001 301 304 1101001 305 308 ...

Страница 6: ...SERVICE INFORMATION DDS 3600R RELAY PACK SERVICE INFORMATION Software Revision 1 0 Version C UL Versions 6 NSI CORPORATION ...

Страница 7: ...epair or replace at its option defective materials provided you have identified yourself as the original owner of the product to NSI or any authorized NSI dealer Transportation charges to and from an authorized dealer or the NSI factory for repair shall be the responsibility of the owner All products returned to NSI must have factory authorization for return prior to shipping NSI Corporation is no...

Отзывы: