background image

Page 2

Table of Contents

INTRODUCTION ................................................................................................................................................... 3

SPECIFICATIONS ................................................................................................................................................. 3

MOUNTING ........................................................................................................................................................... 3

AC POWER CABLE .............................................................................................................................................. 3

AC OUTPUT RECEPTACLES .............................................................................................................................. 3

PERMANENT CONNECTION ............................................................................................................................... 4

AC Input ...................................................................................................................................................... 4
AC Output ................................................................................................................................................... 4

LED INDICATORS ................................................................................................................................................. 4

CHANNEL FUSES ................................................................................................................................................ 4

MICROPLEX MULTIPLEX CONTROL WIRING ................................................................................................... 5

ANALOG 0-10 VDC CONTROL WIRING ............................................................................................................. 5

DMX512 MULTIPLEX CONTROL WIRING ........................................................................................................... 5

AUTO LAMP TEST ............................................................................................................................................... 5

INTERNAL CONFIGURATION DIP SWITCH SELECTION .................................................................................. 6

Softstart ...................................................................................................................................................... 6
NON DIM Channels (Relay Mode) ............................................................................................................. 6

AUTO SEQUENCING MODE ................................................................................................................................ 6

INSTALLATION AND OPERATION TIPS ............................................................................................................. 6

ADDRESSING ....................................................................................................................................................... 7

Page 7

ADDRESSING

When using any of the multiplex control systems, the DIP switches on the front panel of the DDS 6000 must
be set to assign the desired dimmer channels. The switches control the dimmer channels in groups of four.
See the following chart for settings.

When the automatic sequencing feature is operating, the DIP switch selects the operating sequence pattern
and speed. See the section on INTERNAL CONFIGURATION DIP SWITCH SELECTION for details.

CONTROL

1-4

13-16

25-28

37-40

49-52

61-64

73-76

85-88

97-100

109-112

121-124

133-136

145-148

157-160

169-172

181-184

193-196

205-208

217-220

229-232

241-244

253-256

265-268

277-280

289-292

301-304

313-316

325-328

337-340

349-352

361-364

373-376

385-388

397-400

409-412

421-424

433-436

445-448

457-460

469-472

481-484

493-496

505-508

DIP SWITCH CHANNEL ASSIGNMENTS (1=up, 0=down)

1234567

0100000

1010000

0001000

1101000

0111000

1000100

0010100

1110100

0101100

1011100

0000010

1100010

0110010

1001010

0011010

1111010

0100110

1010110

0001110

1101110

0111110

1000001

0010001

1110001

0101001

1011001

0000101

1100101

0110101

1001101

0011101

1111101

0100011

1010011

0001011

1101011

0111011

1000111

0010111

1110111

0101111

1011111

1234567

0000000

1100000

0110000

1001000

0011000

1111000

0100100

1010100

0001100

1101100

0111100

1000010

0010010

1110010

0101010

1011010

0000110

1100110

0110110

1001110

0011110

1111110

0100001

1010001

0001001

1101001

0111001

1000101

0010101

1110101

0101101

1011101

0000011

1100011

0110011

1001011

0011011

1111011

0100111

1010111

0001111

1101111

0111111

CONTROL

5-8

17-20

29-32

41-44

53-56

65-68

77-80

89-92

101-104

113-116

125-128

137-140

149-152

161-164

173-176

185-188

197-200

209-212

221-224

233-236

245-248

257-260

269-272

281-284

293-296

305-308

317-320

329-332

341-344

353-356

365-368

377-380

389-392

401-404

413-416

425-428

437-440

449-452

461-464

473-476

485-488

497-500

509-512

1234567

1000000

0010000

1110000

0101000

1011000

0000100

1100100

0110100

1001100

0011100

1111100

0100010

1010010

0001010

1101010

0111010

1000110

0010110

1110110

0101110

1011110

0000001

1100001

0110001

1001001

0011001

1111001

0100101

1010101

0001101

1101101

0111101

1000011

0010011

1110011

0101011

1011011

0000111

1100111

0110111

1001111

0011111

1111111

CONTROL

9-12

21-24

33-36

45-48

57-60

69-72

81-84

93-96

105-108

117-120

129-132

141-144

153-156

165-168

177-180

189-192

201-204

213-216

225-228

237-240

249-252

261-264

273-276

285-288

297-300

309-312

321-324

333-336

345-348

357-360

369-372

381-384

393-396

405-408

417-420

429-432

441-444

453-456

465-468

477-480

489-492

501-504

Содержание DDS 6000+

Страница 1: ...Page 1 PK 93381 10 00 0B DDS 6000 6000 SATELLITE DIMMER PACKS USER GUIDE Software Revision 1 0 and above Document Revised 8 30 02 Copyright 2002 Leviton Manufacturing Co Inc ...

Страница 2: ...AC Input 4 AC Output 4 LED INDICATORS 4 CHANNEL FUSES 4 MICROPLEX MULTIPLEX CONTROL WIRING 5 ANALOG 0 10 VDC CONTROL WIRING 5 DMX512 MULTIPLEX CONTROL WIRING 5 AUTO LAMP TEST 5 INTERNAL CONFIGURATION DIP SWITCH SELECTION 6 Softstart 6 NON DIM Channels Relay Mode 6 AUTO SEQUENCING MODE 6 INSTALLATION AND OPERATION TIPS 6 ADDRESSING 7 ...

Страница 3: ...with the NEMA 5 20 plug will support 2400 Watts The DDS 6000 Plus includes two cords one per each two channels which doubles the maximum capacity The power cord s must be connected to a power source capable of supplying the total power drawn by the lights See SPECIFICATIONS for details on maximum power capability AC OUTPUT RECEPTACLES The DDS 6000 has two AC receptacles for each channel These rece...

Страница 4: ...rcuits 1 through 4 are terminated to their respective terminals labeled Load and Load N Circuits 1 and 2 are supplied from input A and circuits 3 and 4 from input B The control power supply is also supplied by input A Terminal rating are the same as indicated above for line terminals LED INDICATORS The front panel indicator LEDs indicate the status of the relay RED Indicates the firing card is rec...

Страница 5: ...control console or device you are using for the proper connections The control input impedance is 4 7K ohms DMX512 MULTIPLEX CONTROL WIRING DMX512 is the United States Institute of Theater Technology USITT standard for the digital control of dimmers Leviton NSI DDS dimmer products can be converted from Microplex to DMX512 digital multiplex with a simple kit available from your dealer DMX512 is the...

Страница 6: ...osition on the firing cards as indicated below Moving the switch to ON will restore dimming operation AUTO SEQUENCING MODE The DDS 6000 dimmers can be configured to perform stand alone Automatic Sequencing in place of Auto Lamp Test This is useful for lighting displays and show windows The four channels will automatically fade from one to another in a preprogrammed pattern and time selected by the...

Страница 7: ...11111 1234567 0000000 1100000 0110000 1001000 0011000 1111000 0100100 1010100 0001100 1101100 0111100 1000010 0010010 1110010 0101010 1011010 0000110 1100110 0110110 1001110 0011110 1111110 0100001 1010001 0001001 1101001 0111001 1000101 0010101 1110101 0101101 1011101 0000011 1100011 0110011 1001011 0011011 1111011 0100111 1010111 0001111 1101111 0111111 CONTROL 5 8 17 20 29 32 41 44 53 56 65 68 ...

Страница 8: ... for labor for removal of this product or reinstallation This warranty is void if this product is installed improperly or in an improper environment overloaded misused opened abused or altered in any manner or is not used under normal operating conditions or not in accordance with any labels or instructions There are no other or implied warranties of any kind including merchantability and fitness ...

Отзывы: