background image

2

Levenhuk DTX 700 

Mobi

Digital Microscope 

Microscope parts

Capture 
Zoom adjustment wheel 
Polarizing wheel 
Battery status indicator 
HDMI out 
AV out 
DC: charge battery
USB: output to PC 
Objective lens 
1/4" screw  
MicroSD slot 
Focus wheel

Brightness adjustment wheel 
Battery compartment 
4" color LCD display 
Speaker 
Setup
Power on/off
Up
Photo/Video/Playback
OK (Confirm) 
Down 
Microphone

The kit includes

: microscope, tripod, rechargeable battery, USB cable, AV cable, 

power adapter, software CD, pouch, user manual and lifetime warranty.

Microscope assembly

Open the battery compartment and insert the battery into the battery 

compartment matching the indicated polarity. The battery has to be fully charged 

before turning the microscope on for the first time. Plug the power cable into the 

power cable socket on the microscope body (7) and connect it to a power source. 

The battery status indicator (4) will turn red. Once the battery is fully charged, 

the indicator will go out. You can now disconnect the microscope from the power 

source and turn it on. The fully-charged battery allows you to use the microscope 

for 2.5 hours. The illumination will grow dim and the image quality will decrease 

to inform you that the battery is low. Charge the battery, as described above.
A microSD card (purchased separately) is required to save captured images and 

recorded videos. Turn the microscope off and insert the microSD card into the 

corresponding slot on the microscope body until it locks in place with a click. Do 

not apply excessive force when inserting the microSD card. Try rotating the card, 

if it does not lock in place with ease. Format the card before using it. To turn the 

microscope on, open the LCD display or press the power button (17). To turn the 

microscope off, fold the LCD display or press the power button (17) again (refer to 

Power saving section for more information).

Display icons

Note:

 Interface icons will be hidden if no key has been pressed and held for 10 seconds. 

Capturing an image

Turn the microscope on and point it at an object. Make sure the LCD display 

is fully unfolded. Adjust the illumination brightness, so that the specimen is 

evenly lit. Change magnification, then focus your view and press the capture 

button (1) to capture an image.

Recording a video

Press the Photo/Video/Playback button (19) to switch to video mode. The icon in 

the upper left corner of the screen will change in confirmation. Press the capture 

button (1) to start recording and press it again to stop.

EN

Never, under any circumstances, look directly at the Sun, another bright 

source of light or at a laser through this device, as this may cause 

PERMANENT RETINAL DAMAGE and may lead to BLINDNESS.

 

  

 
 
 
 
 
 
 

 

Capture an 

image

Playback mode

Current image 

resolution

Battery status 

indicator

Start and stop video 

recording
Total number of images that 

may be captured (based on the 

current resolution)

MicroSD status icon

Содержание DTX 700 Mobi

Страница 1: ...croscope User Manual Ръководство за потребителя Návod k použití Bedienungsanleitung Guía del usuario Használati útmutató Guida all utilizzo Instrukcja obsługi Manual do usuário Инструкция по эксплуатации EN BG CZ DE ES HU IT PL PT RU ...

Страница 2: ...orded videos Turn the microscope off and insert the microSD card into the corresponding slot on the microscope body until it locks in place with a click Do not apply excessive force when inserting the microSD card Try rotating the card if it does not lock in place with ease Format the card before using it To turn the microscope on open the LCD display or press the power button 17 To turn the micro...

Страница 3: ...ry Display menu Press Setup button 16 to open the main display menu From this menu you can set image and video resolution the interface language date and time turn on the power saving mode set up the TV connection format the SD card reset settings and check the hardware version Also this menu provides access to the Loop recording mode and Date Stamp option Resolution Select the image or video reso...

Страница 4: ... separate window Click the corresponding icon on the toolbar to begin calibration Using your mouse choose two points on the image you have to know the actual distance between these two points Once you choose the second point a dialog window will open where you have to enter the known distance in the Actual dimension field The application will automatically calculate the magnification of the image ...

Страница 5: ...lown off or brushed away with a soft brush Do not apply excessive pressure when adjusting focus Do not overtighten the locking screws Protect the device from sudden impact and excessive mechanical force Store the device in a dry cool place away from hazardous acids and other chemicals away from heaters open fire and other sources of high temperatures Do not use the device for lengthy periods of ti...