1000BASE-T Pin Assignments
All 1000BASE-T ports support automatic MDI/MDI-X operation, so you
can use straight-through cables for all network connections to PCs or
servers, or to other switches or hubs.
The table below shows the 1000BASE-T MDI and MDI-X port pinouts.
These ports require that all four pairs of wires be connected. Note that for
1000BASE-T operation, all four pairs of wires are used for both transmit
and receive.
Use 100-ohm Category 5, 5e or 6 unshielded twisted-pair (UTP) or
shielded twisted-pair (STP) cable for 1000BASE-T connections. Also be
sure that the length of any twisted-pair connection does not exceed 100
meters (328 feet).
Cable Testing for Existing Category 5 Cable
Installed Category 5 cabling must pass tests for Attenuation, Near-End
Crosstalk (NEXT), and Far-End Crosstalk (FEXT). This cable testing
information is specified in the ANSI/TIA/EIA-TSB-67 standard.
Additionally, cables must also pass test parameters for Return Loss and
Equal-Level Far-End Crosstalk (ELFEXT). These tests are specified in the
ANSI/TIA/EIA-TSB-95 Bulletin, “The Additional Transmission
Performance Guidelines for 100 Ohm 4-Pair Category 5 Cabling.”
Table B-2 1000BASE-T MDI and MDI-X Port Pinouts
Pin
MDI Signal Name
MDI-X Signal Name
1
Bi-directional Data One Plus (BI_D1+)
Bi-directional Data Two Plus (BI_D2+)
2
Bi-directional Data One Minus (BI_D1-)
Bi-directional Data Two Minus (BI_D2-)
3
Bi-directional Data Two Plus (BI_D2+)
Bi-directional Data One Plus (BI_D1+)
4
Bi-directional Data Three Plus (BI_D3+)
Bi-directional Data Four Plus (BI_D4+)
5
Bi-directional Data Three Minus (BI_D3-)
Bi-directional Data Four Minus (BI_D4-)
6
Bi-directional Data Two Minus (BI_D2-)
Bi-directional Data One Minus (BI_D1-)
7
Bi-directional Data Four Plus (BI_D4+)
Bi-directional Data Three Plus (BI_D3+)
8
Bi-directional Data Four Minus (BI_D4-)
Bi-directional Data Three Minus (BI_D3-)
Содержание GSW-1676
Страница 1: ...GSW 1676 GSW 2476 User Manual...
Страница 2: ......
Страница 16: ...FIGURES xvi...
Страница 58: ...CONFIGURING THE SWITCH 6 10 Figure 6 3 Status Overview...
Страница 62: ...CONFIGURING THE SWITCH 6 14 Web Click STATUS Statistics Figure 6 4 Port Statistics...
Страница 71: ...STATIC MAC 6 23 Figure 6 13 Counter Configuration...
Страница 88: ...CONFIGURING THE SWITCH 6 40 Web Click VLANS VLAN Membership Figure 6 24 802 1Q VLAN Configuration...
Страница 109: ...802 1X 6 61 Figure 6 32 802 1X Configuration...
Страница 113: ...802 1X 6 65 Web Click 802 1X Statistics Figure 6 33 802 1X Statistics...
Страница 128: ...TROUBLESHOOTING A 4...
Страница 138: ...SPECIFICATIONS C 4...
Страница 144: ...GLOSSARY Glossary 6...
Страница 148: ...INDEX Index 4...
Страница 149: ......
Страница 150: ...GSW 1676 GSW 2476 E052010 CS R02 149100011100H...