Switch#show poe interfaces status
Interface Power Power Curr Avg Peak Curr Trouble PD
Control Status Power Power Power Current Cause Class
-------------------------------------------------------------------------------------------
* Gi0/1 Normal Powering 2.138W 2.217W 2.296W 40mA 0 3
* Gi0/2 Normal Powering 17.106W 17.186W 17.267W 320mA 0 4
Gi0/3 Normal Detecting 0W 0W 0W 0mA 0 N/A
Gi0/4 Normal Detecting 0W 0W 0W 0mA 0 N/A
Gi0/5 Normal Detecting 0W 0W 0W 0mA 0 N/A
Gi0/6 Normal Detecting 0W 0W 0W 0mA 0 N/A
Gi0/7 Normal Detecting 0W 0W 0W 0mA 0 N/A
Gi0/8 Normal Detecting 0W 0W 0W 0mA 0 N/A
Display all POE port configuration information:
Switch#show poe interfaces configuration
Interface Power Power Max Alloc Port Port
Control Status Power Power Priority Legacy
-----------------------------------------------------------------
* Gi0/1 Normal Powering 30W 20W High N/A
* Gi0/2 Normal Powering 30W 30W High N/A
Gi0/3 Normal Detecting 15.123W 30W Critical N/A
Gi0/4 Normal Detecting 30W 30W Critical N/A
Gi0/5 Normal Detecting 30W 0W Low N/A
Gi0/6 Normal Detecting 30W 0W Low N/A
Gi0/7 Normal Detecting 30W 0W Low N/A
Gi0/8 Normal Detecting 30W 0W Low N/A
I
D
Port trouble cause
Instructions
0
None
Normal power supply
1
Overload During Startup
Detection stage, found that the current is too big and
disconnect
2
Power Overload due to Icut
PD equipment overload and disconnect the power
3
Short Circuit Detected
PD equipment short circuit and broken
4
Thermal Powerdown
High temperature protection and shut down
5
Power Management
Shut down power management
6
VEE UVLO
Hardware fault and shut down