39
11.3 Scheduled Event
Click New to open the recording setting page. In this page, the user can define the recording
schedule and recording capacity.
Name - Enter a descriptive name for the recording setting.
Event - Select the event type from the drop-down menu
Time - Specify the recording duration.
11.4 DI/DO
Digital Input - The DI socket allows the IP camera to receive input from an external device.
The external device should have the ability to drive voltage on the connected DI wire to the triggering
voltage level in order to notify the IP camera of any event of interest. The IP camera will then process
the event notification according to the specific event rules.
Triggering voltage Level: LOW, HIGH, Rising and Falling.
Users should select the option according to the capability of their external device.
Digital Output - The DO socket allows the IP camera to send output to an external device. While
executing the DO notification action, the IP camera drives voltage on the connected DO wire to the
triggering voltage level for X number of seconds. The connected external device will then be triggered
for X number of seconds.
Triggered Voltage Level - OPEN or GROUND
Users should select the option according to the specification of their external device.