Mounting
Leuze electronic GmbH + Co. KG
MSI-TR1B / MSI-TR2B
18
Deflecting mirrors
When using deflecting mirrors, the following must be observed:
• Range loss per deflecting mirror of approx. 15 %.
• Deflecting mirrors must not be soiled.
• Environmental conditions (vapors or dust-laden air considerably limit the range).
• Arrange the deflecting mirror so that the optical axis is aligned with the center of the mirror
Figure 6.6: Arrangement of the deflecting mirrors
6.1.4 Checklist – mounting the protective sensor
Interval: once prior to establishing the electrical connection
Tester: competent person
Table 6.4:
Checklist – mounting the protective sensor
Items on the check list
Yes
No
Do the beam heights satisfy the requirements acc. to EN ISO 13855 (see table 6.1)?
Is the safety distance to the point of operation maintained (see chapter 6.1.1 "Calculat
Is the minimum distance to reflective surfaces maintained (see chapter 6.1.3 "Minimum
distance to reflective surfaces")?
Is it ensured that protective sensors cannot mutually influence one another?
Can the point of operation or the danger zone only be accessed through the protective
field?
Is it ensured that the protective field cannot be circumvented?
Do the transmitter and receiver connections point in the same direction?
Is the protective sensor mounted acc. to the corresponding instructions provided by the
manufacturer?