background image

KRT18BW. …2… 

2022/04/08

Order guide

The sensors listed here are preferred types; current information at www.leuze.com

Mounting adapter BTX 018M

With the help of mounting adapter BTX 018M (part no. 50133412), contrast sensors KRT18B… can be mounted on existing mounting 

devices for contrast sensors in the standard design (80mm x 53mm x 30mm).

Order code

Part no.

Features

KRT18BW.H2/G6T-M12

50147611

Light spot orientation horizontal (transverse), antivalent push-pull outputs, potentiometer with bar graph 

Selectable additional function: light/dark switching

KRT18BW.V2/G6T-M12

50147605

Light spot orientation vertical (lengthwise), antivalent push-pull outputs, potentiometer with bar graph 

Selectable additional function: light/dark switching

Accessories

BTX 018M 

50133412

Mounting adapter for mounting on mounting devices for sensors in the standard design (80 mm x 53 mm x 30 mm)

KRT18BW

Содержание KRT18BW

Страница 1: ...trol cable Blocking of all operational controls via con trol cable Accessories available separately Mounting systems BTU 200M BT 95 Mounting adapter for standard design 80 mm x 53 mm x 30 mm BTX 018M...

Страница 2: ...t temp operation storage 40 C 60 C 40 C 70 C Protective circuit 3 3 2 polarity reversal protection 3 short circuit protection for all transistor outputs 2 3 VDE protection class 4 4 Rating voltage 50V...

Страница 3: ...r with bar graph signal display light dark switching via button Pin assignment of connector pin 4 black cable wire OUT1 G Push pull switching output PNP dark switching dark on NPN light switching ligh...

Страница 4: ...er code Part no Features KRT18BW H2 G6T M12 50147611 Light spot orientation horizontal transverse antivalent push pull outputs potentiometer with bar graph Selectable additional function light dark sw...

Страница 5: ...he mark under the light spot If the bar graph indicator is to the right of the middle position turn the multiturn potentiometer counterclockwise until the sensor switches on yellow indicator LED Q1 on...

Страница 6: ...tton longer than 12s Release the button To change the setting again push the button again for longer than 12 s and release Only the green LED flashes 1 Only for devices without analog output 12s L D R...

Страница 7: ...switching light on OUT1 Locking all operational controls via the IN input Pin 5 A static HIGH signal 20ms at the IN input Pin 5 locks all operational controls on the sensor if required such that no ma...

Отзывы: