Technical data

Optical data

Operating range

13mm ± 3mm

Light source 

1)

1) Average life expectancy 100,000h at an ambient temperature of 25°C

White LED

Light spot dimensions

1mm x 4mm (at a distance of 13 mm)

Light spot orientation

Vertical (lengthwise) or horizontal (transverse)

Time behavior

Switching frequency

15kHz

Response time

33µs

Readiness delay

< 300ms

Electrical data

Operating voltage U

B

 

2)

2) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC

12 … 30VDC (incl. residual ripple)

Residual ripple

15 % of U

B

Open-circuit current

25mA (at 24V)

Switching outputs/functions

OUT1 Push-pull, PNP dark switching (dark on), 

NPN light switching (light on), changeover-capable

OUT2 Push-pull, PNP light switching (light on), 

NPN dark switching (dark on), changeover-capable

Signal voltage high/low

(U

B

-2V)/

2V

Output current

Max. 100mA

Input

IN Configuration input and blocking of the operational controls

Indicators

Green LED continuous light

Ready

Yellow LED continuous light

Switching signal - dark switching (dark on)

Bar graph

Reception signal strength, 13-level

Yellow LEDs - special functions

Light/dark switching

Mechanical data

Housing 

Diecast zinc, chemically nickel-plated

Connector 

Diecast zinc, chemically nickel-plated

Optics

PMMA

Operation

Multiturn potentiometer for sensitivity adjustment, 

button for changing between light/dark switching

Weight

60g

Connection type 

M12 connector, 5-pin

Environmental data

Ambient temp. (operation/storage)

-40°C … +60°C/-40°C … +70°C

Protective circuit 

3)

3) 2=polarity reversal protection, 3=short circuit protection for all transistor outputs

2, 3

VDE protection class 

4)

4) Rating voltage 50V

III

Degree of protection

IP67, IP 69K

Light source

Exempt group (in acc. with EN 62471)

Standards applied

IEC 60947-5-2

Certifications

UL 508, C22.2 No.14-13 

2)

 

5)

 

6)

 

7)

 

8)

5) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.24A min, 

in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)

6) For use in NFPA 79 applications only.

7) Adapters providing field wiring means are available from the manufacturer. Refer to manufacturers information.

8) Caution – Use of controls or adjustments or performance of procedures other than specified herein may result in

hazardous light exposure.

Chemical resistance

Tested in accordance with ECOLAB

Additional functions

Full control of the application

13-level bar graph signal display on the device

Light/dark switching (L/D)

Can be activated via control button

KRT18BW

Notes

Glossy objects: 

With glossy objects, the 

sensor is to be fastened at 

an inclination of 

approx. 10° … 15° rela

-

tive to the object surface.

Alignment aid: 

An alignment aid is 

included in the scope of 

delivery of each sensor. 

This facilitates simple 

alignment of the sensor to 

the working distance of 13 

mm without needing to 

perform electrical 

commissioning.

Observe intended use!

This product is not a safety 

sensor and is not intended 

as personnel protection.

The product may only be put 

into operation by competent 

persons.

Only use the product in ac

-

cordance with its intended 

use.

10°…15°

13 

mm

13 

mm

Содержание KRT18BW

Страница 1: ...trol cable Blocking of all operational controls via con trol cable Accessories available separately Mounting systems BTU 200M BT 95 Mounting adapter for standard design 80 mm x 53 mm x 30 mm BTX 018M...

Страница 2: ...t temp operation storage 40 C 60 C 40 C 70 C Protective circuit 3 3 2 polarity reversal protection 3 short circuit protection for all transistor outputs 2 3 VDE protection class 4 4 Rating voltage 50V...

Страница 3: ...r with bar graph signal display light dark switching via button Pin assignment of connector pin 4 black cable wire OUT1 G Push pull switching output PNP dark switching dark on NPN light switching ligh...

Страница 4: ...er code Part no Features KRT18BW H2 G6T M12 50147611 Light spot orientation horizontal transverse antivalent push pull outputs potentiometer with bar graph Selectable additional function light dark sw...

Страница 5: ...he mark under the light spot If the bar graph indicator is to the right of the middle position turn the multiturn potentiometer counterclockwise until the sensor switches on yellow indicator LED Q1 on...

Страница 6: ...tton longer than 12s Release the button To change the setting again push the button again for longer than 12 s and release Only the green LED flashes 1 Only for devices without analog output 12s L D R...

Страница 7: ...switching light on OUT1 Locking all operational controls via the IN input Pin 5 A static HIGH signal 20ms at the IN input Pin 5 locks all operational controls on the sensor if required such that no ma...

Отзывы: