Product description
Leuze electronic GmbH & Co. KG
CSL 505
14
3.5.5.3
Autom. beam bl. delay [s]
Time that must pass before a beam interruption is blanked. Specified in seconds.
Input option:
0…255
Factory setting:
0
3.5.5.4
Maximum automatic beam blanking
Permanently interrupted beams can be blanked automatically.
Automatic beam blanking
is used to set how many adjacent beams of the same type (e.g. parallel
beams) are allowed to be blanked. The count restarts after an active beam.
Example
Automatic beam blanking = 1
Beam 3, 5 and 8 can be blanked. If beam 9 is additionally covered, this beam is not blanked and the
CSL 505 switching light curtain remains interrupted.
This function is often used for elevator applications and enables permanently interrupted beams to
be blanked automatically.
Automatic beam blanking
0
None
1
1 beam
2
2 beams of same type
...
...
Table 3:
Automatic beam blanking
3.5.6
Start beam of second switching range
With
Start beam of second switching range
you split the CSL 505 switching light curtain into two
ranges.
The state of the ranges is indicated at the outputs pin 2 and pin 4.
Output functions
Pin 2
Pin 4
Normal
Range
1
Range
2
Normal with inverted warning output
Range
1
Range 2 inv.
Swapped
Range
2
Range
1
Swapped with inverted warning
output
Range 2 inv.
Range
1
Swapped without warning output
Range
1
Antivalent
Range
1
Range 1 inv.
Table 4:
Output functions
NOTE
•
Switching ranges with non-parallel beams overlap.
•
If the synchronization beam is interrupted, both ranges switch.
•
The dark switching or hell switching (factory setting) parameter applies to both
ranges.
•
If "1" is selected, the two ranges together cover the entire monitoring range.
•
Smoothing
can be defined for each range